Source code for ms_deisotope.data_source.metadata.instrument_components

from __future__ import print_function
from typing import List, Union
from ms_deisotope.data_source.metadata.software import Software

from ms_deisotope.utils import uid


from .cv import Term, TermSet, render_list


[docs]class Component(Term): """Describes a named component of a mass spectrometer, either using a controlled-vocabulary term or user-defined name. A :class:`Component` is equal to its name and its controlled vocabulary identifier. """ pass
# [[[cog # import cog # from ms_deisotope.data_source.metadata.cv import render_list # render_list('ionization type', term_cls_name="Component", writer=cog.out) # ]]] # CV Version: 4.1.95 ionization_types = TermSet([ Component('chemical ionization', 'MS:1000071', ('The formation of a new ion by the reaction of a neutral ' 'species with an ion. The process may involve transfer of an ' 'electron, a proton or other charged species between the ' 'reactants. When a positive ion results from chemical ' 'ionization the term may be used without qualification. When ' 'a negative ion results the term negative ion chemical ' 'ionization should be used. Note that this term is not ' 'synonymous with chemi-ionization.'), 'ionization type', ['ionization type']), Component('electrospray ionization', 'MS:1000073', ('A process in which ionized species in the gas phase are ' 'produced from an analyte-containing solution via highly ' 'charged fine droplets, by means of spraying the solution ' 'from a narrow-bore needle tip at atmospheric pressure in the ' 'presence of a high electric field. When a pressurized gas is ' 'used to aid in the formation of a stable spray, the term ' 'pneumatically assisted electrospray ionization is used. The ' 'term ion spray is not recommended.'), 'ionization type', ['ionization type']), Component('fast atom bombardment ionization', 'MS:1000074', ('The ionization of any species by the interaction of a ' 'focused beam of neutral atoms having a translational energy ' 'of several thousand eV with a sample that is typically ' 'dissolved in a solvent matrix. See also secondary ' 'ionization.'), 'ionization type', ['ionization type']), Component('multiphoton ionization', 'MS:1000227', ('Photoionization of an atom or molecule in which in two or ' 'more photons are absorbed.'), 'ionization type', ['ionization type']), Component('atmospheric pressure ionization', 'MS:1000240', ('Any ionization process in which ions are formed in the gas ' 'phase at atmospheric pressure.'), 'ionization type', ['ionization type']), Component('desorption ionization', 'MS:1000247', ('The formation of ions from a solid or liquid material after ' 'the rapid vaporization of that sample.'), 'ionization type', ['ionization type']), Component('flowing afterglow', 'MS:1000255', ('An ion source immersed in a flow of helium or other inert ' 'buffer gas that carries the ions through a meter-long ' 'reactor at pressures around 100 Pa.'), 'ionization type', ['ionization type']), Component('field ionization', 'MS:1000258', ('The removal of electrons from any species by interaction ' 'with a high electric field.'), 'ionization type', ['ionization type']), Component('glow discharge ionization', 'MS:1000259', ('The formation of ions in the gas phase and from solid ' 'samples at the cathode by application of a voltage to a low ' 'pressure gas.'), 'ionization type', ['ionization type']), Component('Negative Ion chemical ionization', 'MS:1000271', ('Chemical ionization that results in the formation of ' 'negative ions.'), 'ionization type', ['ionization type']), Component('neutralization reionization mass spectrometry', 'MS:1000272', ('With this technique, m/z selected ions form neutrals by ' 'charge transfer to a collision gas or by dissociation. The ' 'neutrals are separated from the remaining ions and ionized ' 'in collisions with a second gas. This method is used to ' 'investigate reaction intermediates and other unstable ' 'species.'), 'ionization type', ['ionization type']), Component('photoionization', 'MS:1000273', ('The ionization of an atom or molecule by a photon, written M ' '+ h? ? M^+ + e. The term photon impact is not recommended.'), 'ionization type', ['ionization type']), Component('pyrolysis mass spectrometry', 'MS:1000274', ('A mass spectrometry technique in which the sample is heated ' 'to the point of decomposition and the gaseous decomposition ' 'products are introduced into the ion source.'), 'ionization type', ['ionization type']), Component('resonance enhanced multiphoton ionization', 'MS:1000276', ('Multiphoton ionization in which the ionization cross section ' 'is significantly enhanced because the energy of the incident ' 'photons is resonant with an intermediate excited state of ' 'the neutral species.'), 'ionization type', ['ionization type']), Component('adiabatic ionization', 'MS:1000380', ('A process whereby an electron is removed from an atom, ion, ' 'or molecule to produce an ion in its lowest energy state.'), 'ionization type', ['ionization type']), Component('associative ionization', 'MS:1000381', ('An ionization process in which two excited atoms or ' 'molecules react to form a single positive ion and an ' 'electron.'), 'ionization type', ['ionization type']), Component('autodetachment', 'MS:1000383', ('The formation of a neutral when a negative ion in a discrete ' 'state with an energy greater than the detachment threshold ' 'loses an electron spontaneously without further interaction ' 'with an energy source.'), 'ionization type', ['ionization type']), Component('autoionization', 'MS:1000384', ('The formation of an ion when an atom or molecule in a ' 'discrete state with an energy greater than the ionization ' 'threshold loses an electron spontaneously without further ' 'interaction with an energy source.'), 'ionization type', ['ionization type']), Component('charge exchange ionization', 'MS:1000385', ('The interaction of an ion with an atom or molecule in which ' 'the charge on the ion is transferred to the neutral without ' 'the dissociation of either. Synonymous with charge transfer ' 'ionization.'), 'ionization type', ['ionization type']), Component('chemi-ionization', 'MS:1000386', ('The reaction of a neutral molecule with an internally ' 'excited molecule to form an ion. Note that this term is not ' 'synonymous with chemical ionization.'), 'ionization type', ['ionization type']), Component('dissociative ionization', 'MS:1000388', ('The reaction of a gas-phase molecule that results in its ' 'decomposition to form products, one of which is an ion.'), 'ionization type', ['ionization type']), Component('electron ionization', 'MS:1000389', ('The ionization of an atom or molecule by electrons that are ' 'typically accelerated to energies between 50 and 150 eV. ' 'Usually 70 eV electrons are used to produce positive ions. ' "The term 'electron impact' is not recommended."), 'ionization type', ['ionization type']), Component('liquid secondary ionization', 'MS:1000395', ('The ionization of any species by the interaction of a ' 'focused beam of ions with a sample that is dissolved in a ' 'solvent matrix. See also fast atom bombardment and secondary ' 'ionization.'), 'ionization type', ['ionization type']), Component('penning ionization', 'MS:1000399', ('Ionization that occurs through the interaction of two or ' 'more neutral gaseous species, at least one of which is ' 'internally excited.'), 'ionization type', ['ionization type']), Component('plasma desorption ionization', 'MS:1000400', ('The ionization of material in a solid sample by bombarding ' 'it with ionic or neutral atoms formed as a result of the ' 'fission of a suitable nuclide, typically 252Cf. Synonymous ' 'with fission fragment ionization.'), 'ionization type', ['ionization type']), Component('secondary ionization', 'MS:1000402', ('The process in which ions are ejected from a sample surface ' 'as a result of bombardment by a primary beam of atoms or ' 'ions.'), 'ionization type', ['ionization type']), Component('soft ionization', 'MS:1000403', ('The formation of gas-phase ions without extensive ' 'fragmentation.'), 'ionization type', ['ionization type']), Component('spark ionization', 'MS:1000404', ('The formation of ions from a solid material by an ' 'intermittent electrical discharge.'), 'ionization type', ['ionization type']), Component('surface ionization', 'MS:1000406', ('The ionization of a neutral species when it interacts with a ' 'solid surface with an appropriate work function and ' 'temperature.'), 'ionization type', ['ionization type']), Component('thermal ionization', 'MS:1000407', ('The ionization of a neutral species through contact with a ' 'high temperature surface.'), 'ionization type', ['ionization type']), Component('vertical ionization', 'MS:1000408', ('A process in which an electron is removed from or added to a ' 'molecule without a change in the positions of the atoms. The ' 'resulting ion is typically in an excited vibrational state.'), 'ionization type', ['ionization type']), Component('fast ion bombardment', 'MS:1000446', ('The ionization of any species by the interaction of a ' 'focused beam of ions having a translational energy of ' 'several thousand eV with a solid sample.'), 'ionization type', ['ionization type']), Component('paper spray ionization', 'MS:1003235', ('The ionization of analytes from a piece of paper by applying ' 'a solvent and voltage.'), 'ionization type', ['ionization type']), Component('proton transfer reaction', 'MS:1003248', ('Process to transfer a proton from a hydronium ion (H3O+) to ' 'neutral analyte, leading to a protonated analyte, which ' 'typically does not lead to fragmentation." ' '[DOI:10.1002/mas.20048'), 'ionization type', ['ionization type']), Component('proton transfer charge reduction', 'MS:1003249', ('Process to transfer one or more protons from a multiply ' 'charged cation (peptide or protein ion) to a proton acceptor ' 'anion or neutral basic compound, thereby reducing the charge ' 'of the original analyte.'), 'ionization type', ['ionization type']), Component('microelectrospray', 'MS:1000397', ('Electrospray ionization at a solvent flow rate of 300-800 ' 'nL/min where the flow is a result of a mechanical pump. See ' 'nanoelectrospray.'), 'ionization type', ['electrospray ionization', 'ionization type']), Component('nanoelectrospray', 'MS:1000398', ('Electrospray ionization at a flow rate less than ~25 nL/min. ' 'Nanoelectrospray is synonymous with nanospray. The flow is ' 'dependent on the potenial on the tip of the electrospray ' 'needle and/or a gas presure to push the sample through the ' 'needle. See also electrospray ionization and ' 'microelectrospray.'), 'ionization type', ['electrospray ionization', 'ionization type']), Component('atmospheric pressure chemical ionization', 'MS:1000070', ('Chemical ionization that takes place at atmospheric pressure ' 'as opposed to the reduced pressure is normally used for ' 'chemical ionization.'), 'ionization type', ['atmospheric pressure ionization', 'ionization type']), Component('atmospheric pressure matrix-assisted laser desorption ionization', 'MS:1000239', ('Matrix-assisted laser desorption ionization in which the ' 'sample target is at atmospheric pressure and the ions formed ' 'by the pulsed laser are sampled through a small aperture ' 'into the mass spectrometer.'), 'ionization type', ['atmospheric pressure ionization', 'ionization type']), Component('atmospheric pressure photoionization', 'MS:1000382', ('Atmospheric pressure chemical ionization in which the ' 'reactant ions are generated by photo-ionization.'), 'ionization type', ['atmospheric pressure ionization', 'ionization type']), Component('desorption electrospray ionization', 'MS:1002011', ('Combination of electrospray and desorption ionization method ' 'that ionizes gases, liquids and solids in open air under ' 'atmospheric pressure." [DOI:10.1126/science.1104404'), 'ionization type', ['atmospheric pressure ionization', 'ionization type']), Component('matrix-assisted laser desorption ionization', 'MS:1000075', ('The formation of gas-phase ions from molecules that are ' 'present in a solid or solvent matrix that is irradiated with ' 'a pulsed laser. See also laser desorption/ionization.'), 'ionization type', ['desorption ionization', 'ionization type']), Component('field desorption', 'MS:1000257', ('The formation of gas-phase ions from a material deposited on ' 'a solid surface in the presence of a high electric field. ' 'Because this process may encompass ionization by field ' 'ionization or other mechanisms, it is not recommended as a ' 'synonym for field desorption ionization.'), 'ionization type', ['desorption ionization', 'ionization type']), Component('desorption/ionization on silicon', 'MS:1000387', ('The formation of ions by laser desorption ionization of a ' 'sample deposited on a porous silicon surface.'), 'ionization type', ['desorption ionization', 'ionization type']), Component('laser desorption ionization', 'MS:1000393', ('The formation of gas-phase ions by the interaction of a ' 'pulsed laser with a solid or liquid material.'), 'ionization type', ['desorption ionization', 'ionization type']), Component('surface-assisted laser desorption ionization', 'MS:1000405', ('The formation of gas-phase ions from molecules that are ' 'deposited on a particular surface substrate that is ' 'irradiated with a pulsed laser. See also matrix-assisted ' 'laser desorption ionization.'), 'ionization type', ['desorption ionization', 'ionization type']), Component('surface enhanced laser desorption ionization', 'MS:1000278', ('The formation of ionized species in the gas phase from ' 'analytes deposited on a particular surface substrate which ' 'is irradiated with a laser beam of which wavelength is ' 'absorbed by the surface. See also desorption/ionization on ' 'silicon and laser desorption/ionization.'), 'ionization type', ['surface ionization', 'ionization type']), Component('surface enhanced neat desorption', 'MS:1000279', ('Matrix-assisted laser desorption ionization in which the ' 'matrix is covalently linked to the target surface.'), 'ionization type', ['surface ionization', 'ionization type']), ]) # [[[end]]] # [[[cog # import cog # from ms_deisotope.data_source.metadata.cv import render_list # render_list('detector type', term_cls_name="Component", writer=cog.out) # ]]] # CV Version: 4.1.95 detector_types = TermSet([ Component('channeltron', 'MS:1000107', ('A horn-shaped (or cone-shaped) continuous dynode particle ' 'multiplier. The ion strikes the inner surface of the device ' 'and induces the production of secondary electrons that in ' 'turn impinge on the inner surfaces to produce more secondary ' 'electrons. This avalanche effect produces an increase in ' 'signal in the final measured current pulse.'), 'detector type', ['detector type']), Component('daly detector', 'MS:1000110', ('Detector consisting of a conversion dynode, scintillator and ' 'photomultiplier. The metal knob at high potential emits ' 'secondary electrons when ions impinge on the surface. The ' 'secondary electrons are accelerated onto the scintillator ' 'that produces light that is then detected by the ' 'photomultiplier detector.'), 'detector type', ['detector type']), Component('faraday cup', 'MS:1000112', ('A conducting cup or chamber that intercepts a charged ' 'particle beam and is electrically connected to a current ' 'measuring device.'), 'detector type', ['detector type']), Component('multi-collector', 'MS:1000115', ('A detector system commonly used in inductively coupled ' 'plasma mass spectrometers.'), 'detector type', ['detector type']), Component('photomultiplier', 'MS:1000116', ('A detector for conversion of the ion/electron signal into ' 'photon(s) which are then amplified and detected.'), 'detector type', ['detector type']), Component('electron multiplier', 'MS:1000253', ('A device to amplify the current of a beam or packet of ' 'charged particles or photons by incidence upon the surface ' 'of an electrode to produce secondary electrons. The ' 'secondary electrons are then accelerated to other electrodes ' 'or parts of a continuous electrode to produce further ' 'secondary electrons.'), 'detector type', ['detector type']), Component('array detector', 'MS:1000345', ('Detector comprising several ion collection elements, ' 'arranged in a line or grid where each element is an ' 'individual detector.'), 'detector type', ['detector type']), Component('conversion dynode', 'MS:1000346', ('A surface that is held at high potential such that ions ' 'striking the surface produce electrons that are subsequently ' 'detected.'), 'detector type', ['detector type']), Component('dynode', 'MS:1000347', ('One of a series of electrodes in a photomultiplier tube. ' 'Such an arrangement is able to amplify the current emitted ' 'by the photocathode.'), 'detector type', ['detector type']), Component('focal plane collector', 'MS:1000348', ('A detector for spatially disperse ion beams in which all ' 'ions simultaneously impinge on the detector plane.'), 'detector type', ['detector type']), Component('ion-to-photon detector', 'MS:1000349', ('A detector in which ions strike a conversion dynode to ' 'produce electrons that in turn strike a phosphor and the ' 'resulting photons are detected by a photomultiplier.'), 'detector type', ['detector type']), Component('point collector', 'MS:1000350', ('A detector in which the ion beam is focused onto a point and ' 'the individual ions arrive sequentially.'), 'detector type', ['detector type']), Component('postacceleration detector', 'MS:1000351', ('A detector in which the charged particles are accelerated to ' 'a high velocity and impinge on a conversion dynode, emitting ' 'secondary electrons. The electrons are accelerated onto a ' 'phosphor screen, which emits photons that are in turn ' 'detected using a photomultiplier or other photon detector.'), 'detector type', ['detector type']), Component('inductive detector', 'MS:1000624', ('Inductive detector.'), 'detector type', ['detector type']), Component('fluorescence detector', 'MS:1002308', ('A detector using a fluorescent signal after excitation with ' 'light.'), 'detector type', ['detector type']), Component('electron multiplier tube', 'MS:1000111', ('A device to amplify the current of a beam or packet of ' 'charged particles or photons by incidence upon the surface ' 'of an electrode to produce secondary electrons.'), 'detector type', ['electron multiplier', 'detector type']), Component('microchannel plate detector', 'MS:1000114', ('A thin plate that contains a closely spaced array of ' 'channels that each act as a continuous dynode particle ' 'multiplier. A charged particle, fast neutral particle, or ' 'photon striking the plate causes a cascade of secondary ' 'electrons that ultimately exits the opposite side of the ' 'plate.'), 'detector type', ['array detector', 'detector type']), Component('photodiode array detector', 'MS:1000621', ('An array detector used to record spectra in the ultraviolet ' 'and visible region of light.'), 'detector type', ['array detector', 'detector type']), Component('conversion dynode electron multiplier', 'MS:1000108', ('A surface that is held at high potential so that ions ' 'striking the surface produce electrons that are subsequently ' 'detected.'), 'detector type', ['conversion dynode', 'detector type']), Component('conversion dynode photomultiplier', 'MS:1000109', ('A detector in which ions strike a conversion dynode to ' 'produce electrons that in turn generate photons through a ' 'phosphorescent screen that are detected by a ' 'photomultiplier.'), 'detector type', ['conversion dynode', 'detector type']), Component('focal plane array', 'MS:1000113', ('An array of detectors for spatially disperse ion beams in ' 'which all ions simultaneously impinge on the detector plane.'), 'detector type', ['focal plane collector', 'detector type']), Component('Acquity UPLC FLR', 'MS:1000819', ('Acquity UPLC Fluorescence Detector.'), 'detector type', ['Waters instrument model', 'fluorescence detector', 'instrument model', 'detector type']), Component('Acquity UPLC PDA', 'MS:1000818', ('Acquity UPLC Photodiode Array Detector.'), 'detector type', ['Waters instrument model', 'photodiode array detector', 'instrument model', 'array detector', 'detector type']), ]) # [[[end]]] # [[[cog # import cog # from ms_deisotope.data_source.metadata.cv import render_list # render_list('mass analyzer type', 'analyzer_types', term_cls_name="Component", writer=cog.out) # ]]] # CV Version: 4.1.95 analyzer_types = TermSet([ Component('fourier transform ion cyclotron resonance mass spectrometer', 'MS:1000079', ('A mass spectrometer based on the principle of ion cyclotron ' 'resonance in which an ion in a magnetic field moves in a ' 'circular orbit at a frequency characteristic of its m/z ' 'value. Ions are coherently excited to a larger radius orbit ' 'using a pulse of radio frequency energy and their image ' 'charge is detected on receiver plates as a time domain ' 'signal. Fourier transformation of the time domain signal ' 'results in a frequency domain signal which is converted to a ' 'mass spectrum based in the inverse relationship between ' 'frequency and m/z.'), 'mass analyzer type', ['mass analyzer type']), Component('magnetic sector', 'MS:1000080', ('A device that produces a magnetic field perpendicular to a ' 'charged particle beam that deflects the beam to an extent ' 'that is proportional to the particle momentum per unit ' 'charge. For a monoenergetic beam, the deflection is ' 'proportional to m/z.'), 'mass analyzer type', ['mass analyzer type']), Component('quadrupole', 'MS:1000081', ('A mass spectrometer that consists of four parallel rods ' 'whose centers form the corners of a square and whose ' 'opposing poles are connected. The voltage applied to the ' 'rods is a superposition of a static potential and a ' 'sinusoidal radio frequency potential. The motion of an ion ' 'in the x and y dimensions is described by the Matthieu ' 'equation whose solutions show that ions in a particular m/z ' 'range can be transmitted along the z axis.'), 'mass analyzer type', ['mass analyzer type']), Component('time-of-flight', 'MS:1000084', ('Instrument that separates ions by m/z in a field-free region ' 'after acceleration to a fixed acceleration energy.'), 'mass analyzer type', ['mass analyzer type']), Component('electrostatic energy analyzer', 'MS:1000254', ('A device consisting of conducting parallel plates, ' 'concentric cylinders or concentric spheres that separates ' 'charged particles according to their kinetic energy by means ' 'of an electric field that is constant in time.'), 'mass analyzer type', ['mass analyzer type']), Component('ion trap', 'MS:1000264', ('A device for spatially confining ions using electric and ' 'magnetic fields alone or in combination.'), 'mass analyzer type', ['mass analyzer type']), Component('stored waveform inverse fourier transform', 'MS:1000284', ('A technique to create excitation waveforms for ions in FT- ' 'ICR mass spectrometer or Paul ion trap. An excitation ' 'waveform in the time-domain is generated by taking the ' 'inverse Fourier transform of an appropriate frequency-domain ' 'programmed excitation spectrum, in which the resonance ' 'frequencies of ions to be excited are included. This ' 'technique may be used for selection of precursor ions in MS2 ' 'experiments.'), 'mass analyzer type', ['mass analyzer type']), Component('cyclotron', 'MS:1000288', ('A device that uses an oscillating electric field and ' 'magnetic field to accelerate charged particles.'), 'mass analyzer type', ['mass analyzer type']), Component('orbitrap', 'MS:1000484', ('An ion trapping device that consists of an outer barrel-like ' 'electrode and a coaxial inner spindle-like electrode that ' 'form an electrostatic field with quadro-logarithmic ' 'potential distribution. The frequency of harmonic ' 'oscillations of the orbitally trapped ions along the axis of ' 'the electrostatic field is independent of the ion velocity ' 'and is inversely proportional to the square root of m/z so ' 'that the trap can be used as a mass analyzer.'), 'mass analyzer type', ['mass analyzer type']), Component('quadrupole ion trap', 'MS:1000082', ('Quadrupole Ion Trap mass analyzer captures the ions in a ' 'three dimensional ion trap and then selectively ejects them ' 'by varying the RF and DC potentials.'), 'mass analyzer type', ['ion trap', 'mass analyzer type']), Component('linear ion trap', 'MS:1000291', ('A two dimensional Paul ion trap in which ions are confined ' 'in the axial dimension by means of an electric field at the ' 'ends of the trap.'), 'mass analyzer type', ['ion trap', 'mass analyzer type']), Component('axial ejection linear ion trap', 'MS:1000078', ('A linear ion trap mass spectrometer where ions are ejected ' 'along the axis of the analyzer.'), 'mass analyzer type', ['linear ion trap', 'ion trap', 'mass analyzer type']), Component('radial ejection linear ion trap', 'MS:1000083', ('A linear ion trap mass spectrometer where ions are ejected ' 'along the radius of the analyzer.'), 'mass analyzer type', ['linear ion trap', 'ion trap', 'mass analyzer type']), ]) # [[[end]]] # [[[cog # import cog # from ms_deisotope.data_source.metadata.cv import render_list # render_list('inlet type', term_cls_name="Component", writer=cog.out) # ]]] # CV Version: 4.1.95 inlet_types = TermSet([ Component('continuous flow fast atom bombardment', 'MS:1000055', ('Fast atom bombardment ionization in which the analyte in ' 'solution is entrained in a flowing liquid matrix.'), 'inlet type', ['inlet type']), Component('direct inlet', 'MS:1000056', ('The sample is directly inserted into the ion source, usually ' 'on the end of a heatable probe.'), 'inlet type', ['inlet type']), Component('electrospray inlet', 'MS:1000057', ('Inlet used for introducing the liquid sample into an ' 'electrospray ionization source.'), 'inlet type', ['inlet type']), Component('flow injection analysis', 'MS:1000058', ('Sample is directly injected or infused into the ionization ' 'source.'), 'inlet type', ['inlet type']), Component('inductively coupled plasma', 'MS:1000059', ('A gas discharge ion source in which the energy to the plasma ' 'is supplied by electromagnetic induction.'), 'inlet type', ['inlet type']), Component('infusion', 'MS:1000060', ('The continuous flow of solution of a sample into the ' 'ionization source.'), 'inlet type', ['inlet type']), Component('jet separator', 'MS:1000061', ('A device that separates carrier gas from gaseous analyte ' 'molecules on the basis of diffusivity.'), 'inlet type', ['inlet type']), Component('membrane separator', 'MS:1000062', ('A device to separate carrier molecules from analyte ' 'molecules on the basis of ease of diffusion across a ' 'semipermeable membrane.'), 'inlet type', ['inlet type']), Component('moving belt', 'MS:1000063', ('Continuous moving surface in the form of a belt which passes ' 'through an ion source carrying analyte molecules.'), 'inlet type', ['inlet type']), Component('moving wire', 'MS:1000064', ('Continuous moving surface in the form of a wire which passes ' 'through an ion source carrying analyte molecules.'), 'inlet type', ['inlet type']), Component('open split', 'MS:1000065', ('A division of flowing stream of liquid into two streams.'), 'inlet type', ['inlet type']), Component('particle beam', 'MS:1000066', ('Method for generating ions from a solution of an analyte.'), 'inlet type', ['inlet type']), Component('reservoir', 'MS:1000067', ('A sample inlet method involving a reservoir.'), 'inlet type', ['inlet type']), Component('septum', 'MS:1000068', ('A disc composed of a flexible material that seals the ' 'entrance to the reservoir. Can also be entrance to the ' 'vacuum chamber.'), 'inlet type', ['inlet type']), Component('thermospray inlet', 'MS:1000069', ('A method for generating gas phase ions from a solution of an ' 'analyte by rapid heating of the sample.'), 'inlet type', ['inlet type']), Component('direct insertion probe', 'MS:1000248', ('A device for introducing a solid or liquid sample into a ' 'mass spectrometer ion source for desorption ionization.'), 'inlet type', ['inlet type']), Component('direct liquid introduction', 'MS:1000249', ('The delivery of a liquid sample into a mass spectrometer for ' 'spray or desorption ionization.'), 'inlet type', ['inlet type']), Component('membrane inlet', 'MS:1000396', ('A semi-permeable membrane separator that permits the passage ' 'of gas sample directly to the mass spectrometer ion source.'), 'inlet type', ['inlet type']), Component('nanospray inlet', 'MS:1000485', ('Nanospray Inlet.'), 'inlet type', ['electrospray inlet', 'inlet type']), ]) # [[[end]]] all_components = ionization_types + detector_types + analyzer_types + inlet_types # more consistent alias components = all_components all_components_by_name = {c.name: c for c in all_components} def component(name): try: return all_components_by_name[name] except KeyError: return Component(name, name, name, name, [name]) class InstrumentModel(Term): """Describes a named model of a mass spectrometer, either using a controlled-vocabulary term or user-defined name. A :class:`InstrumentModel` is equal to its name and its controlled vocabulary identifier. """ pass # [[[cog # import cog # from ms_deisotope.data_source.metadata.cv import render_list # render_list('instrument model', term_cls_name="InstrumentModel", writer=cog.out) # ]]] # CV Version: 4.1.95 instrument_models = TermSet([ InstrumentModel('SCIEX instrument model', 'MS:1000121', ('The brand of instruments from the joint venture between ' 'Applied Biosystems and MDS Analytical Technologies (formerly ' 'MDS SCIEX). Previously branded as \\"Applied Biosystems|MDS ' 'SCIEX\\".'), 'instrument model', ['instrument model']), InstrumentModel('Bruker Daltonics instrument model', 'MS:1000122', ("Bruker Daltonics' instrument model."), 'instrument model', ['instrument model']), InstrumentModel('Shimadzu instrument model', 'MS:1000124', ('Shimadzu corporation instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('Waters instrument model', 'MS:1000126', ('Waters Corporation instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('Thermo Fisher Scientific instrument model', 'MS:1000483', ('Thermo Fisher Scientific instrument model. The company has ' 'gone through several names including Thermo Finnigan, Thermo ' 'Scientific.'), 'instrument model', ['instrument model']), InstrumentModel('Hitachi instrument model', 'MS:1000488', ('Hitachi instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('Varian instrument model', 'MS:1000489', ('Varian instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('Agilent instrument model', 'MS:1000490', ('Agilent instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('Dionex instrument model', 'MS:1000491', ('Dionex instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('Applied Biosystems instrument model', 'MS:1000495', ('Applied Biosystems instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('LECO instrument model', 'MS:1001800', ('LECO instrument model.'), 'instrument model', ['instrument model']), InstrumentModel('4000 QTRAP', 'MS:1000139', ('Applied Biosystems/MDS SCIEX Q 4000 TRAP MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 150EX', 'MS:1000143', ('Applied Biosystems/MDS SCIEX API 150EX MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 150EX Prep', 'MS:1000144', ('Applied Biosystems/MDS SCIEX API 150EX Prep MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 2000', 'MS:1000145', ('Applied Biosystems/MDS SCIEX API 2000 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 3000', 'MS:1000146', ('Applied Biosystems/MDS SCIEX API 3000 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 4000', 'MS:1000147', ('Applied Biosystems/MDS SCIEX API 4000 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('proteomics solution 1', 'MS:1000186', ('Applied Biosystems/MDS SCIEX Proteomics Solution 1 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Q TRAP', 'MS:1000187', ('Applied Biosystems/MDS SCIEX Q TRAP MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QSTAR', 'MS:1000190', ('Applied Biosystems/MDS SCIEX QSTAR MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('SymBiot I', 'MS:1000194', ('Applied Biosystems/MDS SCIEX SymBiot I MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('SymBiot XVI', 'MS:1000195', ('Applied Biosystems/MDS SCIEX SymBiot XVI MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('3200 QTRAP', 'MS:1000651', ('SCIEX or Applied Biosystems|MDS SCIEX QTRAP 3200.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('4800 Plus MALDI TOF/TOF', 'MS:1000652', ('SCIEX or Applied Biosystems|MDS SCIEX 4800 Plus MALDI TOF- ' 'TOF Analyzer.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 3200', 'MS:1000653', ('SCIEX or Applied Biosystems|MDS SCIEX API 3200 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 5000', 'MS:1000654', ('SCIEX or Applied Biosystems|MDS SCIEX API 5000 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QSTAR Elite', 'MS:1000655', ('SCIEX or Applied Biosystems|MDS SCIEX QSTAR Elite.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QSTAR Pulsar', 'MS:1000656', ('Applied Biosystems|MDS SCIEX QSTAR Pulsar.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QSTAR XL', 'MS:1000657', ('Applied Biosystems|MDS SCIEX QSTAR XL.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QTRAP 5500', 'MS:1000931', ('Applied Biosystems|MDS SCIEX QTRAP 5500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('TripleTOF 5600', 'MS:1000932', ('SCIEX TripleTOF 5600, a quadrupole - quadrupole - time-of- ' 'flight mass spectrometer.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('5800 TOF/TOF', 'MS:1001482', ('SCIEX 5800 TOF-TOF Analyzer.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('TripleTOF 6600', 'MS:1002533', ('SCIEX TripleTOF 6600, a quadrupole - quadrupole - time-of- ' 'flight mass spectrometer.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('2000 QTRAP', 'MS:1002577', ('SCIEX 2000 QTRAP.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('2500 QTRAP', 'MS:1002578', ('SCIEX 2500 QTRAP.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('3500 QTRAP', 'MS:1002579', ('SCIEX 3500 QTRAP.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QTRAP 4500', 'MS:1002580', ('SCIEX QTRAP 4500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QTRAP 6500', 'MS:1002581', ('SCIEX QTRAP 6500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('QTRAP 6500+', 'MS:1002582', ('SCIEX QTRAP 6500+.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('TripleTOF 4600', 'MS:1002583', ('SCIEX TripleTOF 4600 time-of-flight mass spectrometer.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('TripleTOF 5600+', 'MS:1002584', ('SCIEX TripleTOF 5600+ time-of-flight mass spectrometer.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 100', 'MS:1002585', ('Applied Biosystems/MDS SCIEX API 100 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 100LC', 'MS:1002586', ('Applied Biosystems/MDS SCIEX API 100LC MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 165', 'MS:1002587', ('Applied Biosystems/MDS SCIEX API 165 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 300', 'MS:1002588', ('Applied Biosystems/MDS SCIEX API 300 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 350', 'MS:1002589', ('Applied Biosystems/MDS SCIEX API 350 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('API 365', 'MS:1002590', ('Applied Biosystems/MDS SCIEX API 365 MS.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Triple Quad 3500', 'MS:1002591', ('SCIEX Triple Quad 3500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Triple Quad 4500', 'MS:1002592', ('SCIEX Triple Quad 4500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Triple Quad 5500', 'MS:1002593', ('SCIEX Triple Quad 5500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Triple Quad 6500', 'MS:1002594', ('SCIEX Triple Quad 6500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Triple Quad 6500+', 'MS:1002595', ('SCIEX Triple Quad 6500+.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('X500R QTOF', 'MS:1002674', ('SCIEX X500R QTOF, a quadrupole - quadrupole - time-of-flight ' 'mass spectrometer.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Triple Quad 7500', 'MS:1003144', ('SCIEX Triple Quad 7500.'), 'instrument model', ['SCIEX instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics HCT Series', 'MS:1000697', ("Bruker Daltonics' HCT Series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics esquire series', 'MS:1001533', ("Bruker Daltonics' esquire series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics flex series', 'MS:1001534', ("Bruker Daltonics' flex series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics BioTOF series', 'MS:1001535', ("Bruker Daltonics' BioTOF series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics micrOTOF series', 'MS:1001536', ("Bruker Daltonics' micrOTOF series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics amaZon series', 'MS:1001545', ("Bruker Daltonics' amaZon series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics maXis series', 'MS:1001547', ("Bruker Daltonics' maXis series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics solarix series', 'MS:1001548', ("Bruker Daltonics' solarix: ESI quadrupole ion trap, APCI, " 'APPI, ETD, PTR.'), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics apex series', 'MS:1001556', ("Bruker Daltonics' apex series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics SCION series', 'MS:1002293', ("Bruker Daltonics' SCION series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics EVOQ series', 'MS:1002294', ("Bruker Daltonics' EVOQ series."), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Bruker Daltonics timsTOF series', 'MS:1003123', ('Bruker Daltonics timsTOF series'), 'instrument model', ['Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('Shimadzu MALDI-TOF instrument model', 'MS:1000602', ('Shimadzu MALDI-TOF instrument model.'), 'instrument model', ['Shimadzu instrument model', 'instrument model']), InstrumentModel('Shimadzu Scientific Instruments instrument model', 'MS:1000603', ('Shimadzu Scientific Instruments instrument model.'), 'instrument model', ['Shimadzu instrument model', 'instrument model']), InstrumentModel('Auto Spec Ultima NT', 'MS:1000150', ('Waters magnetic sector based AutoSpec Ultima NT MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('GCT', 'MS:1000159', ('Waters oa-ToF based GCT.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('IsoPrime', 'MS:1000164', ('Waters IsoPrime MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('IsoProbe', 'MS:1000165', ('Waters IsoProbe MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('IsoProbe T', 'MS:1000166', ('Waters IsoProbe T MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('M@LDI L', 'MS:1000170', ('Waters oa-ToF based MALDI L.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('M@LDI LR', 'MS:1000171', ('Waters oa-ToF based MALDI LR.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('NG-5400', 'MS:1000180', ('Waters NG-5400 MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Platform ICP', 'MS:1000184', ('Waters Platform ICP MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Q-Tof micro', 'MS:1000188', ('Waters oa-ToF based Q-Tof micro.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Q-Tof Ultima', 'MS:1000189', ('Waters oa-ToF based Q-Tof Ultima.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('quattro micro', 'MS:1000191', ('Waters (triple) quadrupole based micro.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Quattro Ultima', 'MS:1000192', ('Waters (triple) quadrupole based Ultima.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Q-Tof Premier', 'MS:1000632', ('Waters oa-ToF based Q-Tof Premier.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Acquity UPLC PDA', 'MS:1000818', ('Acquity UPLC Photodiode Array Detector.'), 'instrument model', ['Waters instrument model', 'photodiode array detector', 'instrument model', 'array detector', 'detector type']), InstrumentModel('Acquity UPLC FLR', 'MS:1000819', ('Acquity UPLC Fluorescence Detector.'), 'instrument model', ['Waters instrument model', 'fluorescence detector', 'instrument model', 'detector type']), InstrumentModel('ACQUITY UPLC', 'MS:1001761', ('Waters LC-system ACQUITY UPLC.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('ACQUITY UPLC H-Class', 'MS:1001762', ('Waters LC-system ACQUITY UPLC H-Class.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('ACQUITY UPLC H-Class Bio', 'MS:1001763', ('Waters LC-system ACQUITY UPLC H-Class Bio.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('ACQUITY UPLC I-Class', 'MS:1001764', ('Waters LC-system ACQUITY UPLC I-Class.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('ACQUITY UPLC Systems with 2D Technology', 'MS:1001765', ('Waters LC-system ACQUITY UPLC Systems with 2D Technology.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('nanoACQUITY UPLC', 'MS:1001766', ('Waters LC-system nanoACQUITY UPLC.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('nanoACQUITY UPLC System with 1D Technology', 'MS:1001767', ('Waters LC-system nanoACQUITY UPLC System with 1D Technology.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('nanoACQUITY UPLC with HDX Technology', 'MS:1001768', ('Waters LC-system nanoACQUITY UPLC with HDX Technology.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('TRIZAIC UPLC nanoTile', 'MS:1001769', ('Waters LC-system TRIZAIC UPLC nanoTile.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('GCT Premier', 'MS:1001770', ('Waters oa-ToF based GCT Premier.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('MALDI Synapt G2 HDMS', 'MS:1001771', ('Waters oa-ToF based MALDI Synapt G2 HDMS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('MALDI Synapt G2 MS', 'MS:1001772', ('Waters oa-ToF based MALDI Synapt G2 MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('MALDI Synapt G2-S HDMS', 'MS:1001773', ('Waters oa-ToF based MALDI Synapt G2 MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('MALDI Synapt G2-S MS', 'MS:1001774', ('Waters oa-ToF based MALDI Synapt G2-S MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('MALDI Synapt HDMS', 'MS:1001775', ('Waters oa-ToF based MALDI Synapt HDMS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('MALDI Synapt MS', 'MS:1001776', ('Waters oa-ToF based MALDI Synapt MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Synapt G2 HDMS', 'MS:1001777', ('Waters oa-ToF based Synapt G2 HDMS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Synapt G2 MS', 'MS:1001778', ('Waters oa-ToF based Synapt G2 MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Synapt G2-S HDMS', 'MS:1001779', ('Waters oa-ToF based Synapt G2-S HDMS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Synapt G2-S MS', 'MS:1001780', ('Waters oa-ToF based Synapt G2-S MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Synapt HDMS', 'MS:1001781', ('Waters oa-ToF based Synapt HDMS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Synapt MS', 'MS:1001782', ('Waters oa-ToF based Synapt MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo G2 Q-Tof', 'MS:1001783', ('Waters oa-ToF based Xevo G2 Q-Tof.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo G2 Tof', 'MS:1001784', ('Waters oa-ToF based Xevo G2 Tof.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo Q-Tof', 'MS:1001785', ('Waters oa-ToF based Xevo Q-Tof.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('3100', 'MS:1001786', ('Waters quadrupole based 3100.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Acquity SQD', 'MS:1001787', ('Waters quadrupole based Acquity SQD.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Acquity TQD', 'MS:1001788', ('Waters quadrupole based Acquity TQD.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Quattro micro GC', 'MS:1001789', ('Waters (triple) quadrupole based Quattro micro GC.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo TQ MS', 'MS:1001790', ('Waters quadrupole based Xevo TQ MS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo TQD', 'MS:1001791', ('Waters quadrupole based Xevo TQD.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo TQ-S', 'MS:1001792', ('Waters quadrupole based Xevo TQ-S.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('SQ Detector 2', 'MS:1002274', ('Waters quadrupole based SQ Detector 2.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo G2-S Tof', 'MS:1002275', ('Waters oa-ToF based Xevo G2-S Tof.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo G2-S QTof', 'MS:1002276', ('Waters oa-ToF based Xevo G2-S QTof.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('AutoSpec Premier', 'MS:1002277', ('Waters AutoSpec Premier magnetic sector instrument.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('SYNAPT G2-Si', 'MS:1002726', ('Waters Corporation SYNAPT G2-Si orthogonal acceleration ' 'time-of-flight mass spectrometer.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('MALDI SYNAPT G2-Si', 'MS:1002727', ('Waters Corporation MALDI SYNAPT G2-Si orthogonal ' 'acceleration time-of-flight mass spectrometer.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Vion IMS QTof', 'MS:1002728', ('Waters Corporation Vion IMS QTof orthogonal acceleration ' 'time-of-flight mass spectrometer.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo G2-XS Tof', 'MS:1002729', ('Waters Corporation Xevo G2 XS Tof orthogonal acceleration ' 'time-of-flight mass spectrometer.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo TQ-XS', 'MS:1002730', ('Waters Corporation Xevo TQ-XS triple quadrupole mass ' 'spectrometer.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo TQ-S micro', 'MS:1002731', ('Waters Corporation Xevo TQ-S micro triple quadrupole mass ' 'spectrometer.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Synapt XS', 'MS:1003183', ('Waters oa-ToF based Synapt XS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('SELECT SERIES Cyclic IMS', 'MS:1003184', ('Waters oa-ToF based SELECT SERIES Cyclic IMS.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('SELECT SERIES MRT', 'MS:1003185', ('Waters oa-ToF based SELECT SERIES MRT.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Xevo G2-XS QTof', 'MS:1003252', ('Waters Corporation Xevo G2-XS QTof quadrupole time-of-flight ' 'mass spectrometer.'), 'instrument model', ['Waters instrument model', 'instrument model']), InstrumentModel('Thermo Finnigan instrument model', 'MS:1000125', ('ThermoFinnigan from Thermo Electron Corporation instrument ' 'model.'), 'instrument model', ['Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Thermo Electron instrument model', 'MS:1000492', ('Thermo Electron Corporation instrument model.'), 'instrument model', ['Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Finnigan MAT instrument model', 'MS:1000493', ('Finnigan MAT instrument model.'), 'instrument model', ['Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Thermo Scientific instrument model', 'MS:1000494', ('Thermo Scientific instrument model.'), 'instrument model', ['Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('IonSpec instrument model', 'MS:1000123', ('IonSpec corporation instrument model.'), 'instrument model', ['Varian instrument model', 'instrument model']), InstrumentModel('1200 series LC/MSD SL', 'MS:1000467', ('The 1200 Series LC/MSD SL ion trap belongs to the Agilent ' 'LC/MSD ion trap family. It provides fast polarity switching ' 'and multisignal data acquisition capabilities in a single ' 'run while also providing 5 stages of automated data ' 'dependent MS2 and 11 stages of manual MS2.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6110 Quadrupole LC/MS', 'MS:1000468', ('The 6110 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with an entry level ' 'single quadrupole mass spectrometer from the 6100 Series of ' 'Agilent quadrupole mass spectrometers. 6110 Quadrupole mass ' 'spectrometer has m/z range of 10-1500 and 2500 u/s scan ' 'speed. It proves useful for wide range of SIM quantitative ' 'applications.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6120A Quadrupole LC/MS', 'MS:1000469', ('The 6120A Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a single quadrupole ' 'mass spectrometer from the 6100 Series of Agilent mass ' 'spectrometers. 6120 quadrupole mass spectrometer has m/z ' 'range of 10-1500, 2500 u/s scan speed and utilizes multiple ' 'signal acquisition.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6130 Quadrupole LC/MS', 'MS:1000470', ('The 6130 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a single quadrupole ' 'mass spectrometer from the 6100 series of Agilent mass ' 'spectrometers. The 6130 quadrupole mass spectrometer has m/z ' 'range of 2-3000, 2500 u/s scan speed in standard mode and ' '5250 u/s speed in fast-scan mode. It also uses multiple ' 'signal acquisition.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6140 Quadrupole LC/MS', 'MS:1000471', ('The 6140 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a single quadrupole ' 'mass spectrometer from the 6100 Series of Agilent quadrupole ' 'mass spectrometers. 6140 Quadrupole mass spectrometer has ' 'm/z range of 10-1350, 2500 u/s scan speed in standard mode ' 'and 10000 u/s speed in fast-scan mode. It also uses multiple ' 'signal acquisition.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6210 Time-of-Flight LC/MS', 'MS:1000472', ('The 6210 Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer. This time of flight mass ' 'spectrometer has a m/z range of 50-12000, mass accuracy of ' 'less than 2 ppm and resolution greater than 13,000 at m/z ' '2722. It has multiple ion sources and can be used with ' 'multimode ion sources.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6310 Ion Trap LC/MS', 'MS:1000473', ('The 6310 Ion Trap LC/MS is a Agilent liquid chromatography ' 'instrument combined with a 6300 series Agilent ion trap. It ' 'has a mass range of 50-2200 between 0.6 to 0.35 resolution ' 'and mass range of 200-4000 with resolution of 3-4. The scan ' 'speed varies from 1650-27000 for the respective mass ranges.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6320 Ion Trap LC/MS', 'MS:1000474', ('The 6320 Ion Trap LC/MS is a Agilent liquid chromatography ' 'instrument combined with a 6300 series Agilent ion trap. It ' 'has a mass range of 50-2200 between 0.6 to 0.25 resolution ' 'and mass range of 200-4000 with resolution of less than 3. ' 'The scan speed varies from 1650-27000 for the respective ' 'mass ranges.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6330 Ion Trap LC/MS', 'MS:1000475', ('The 6330 Ion Trap LC/MS is a Agilent liquid chromatography ' 'instrument combined with a 6300 series Agilent ion trap. It ' 'has a mass range of 50-2200 between 0.6 to 0.25 resolution ' 'and mass range of 200-4000 with resolution of less than 3. ' 'The scan speed varies from 1650-27000 for the respective ' 'mass ranges.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6340 Ion Trap LC/MS', 'MS:1000476', ('The 6340 Ion Trap LC/MS is a Agilent liquid chromatography ' 'instrument combined with a 6300 series Agilent ion trap. It ' 'has a mass range of 50-2200 between 0.6 to 0.25 resolution ' 'and mass range of 200-4000 with resolution of less than 3. ' 'The scan speed varies from 1650-27000 for the respective ' 'mass ranges.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6410 Triple Quadrupole LC/MS', 'MS:1000477', ('The 6410 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer. Mass range of the mass ' 'spectrometer is 15-1650 m/z, resolution is at three settings ' 'of 0.7 u (unit), 1.2 u (wide) and 2.5 u (widest). The mass ' 'accuracy for 6410 mass spectrometer is 0.1 across the mass ' 'range. The collision cell is a hexapole with linear ' 'acceleration.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('1200 series LC/MSD VL', 'MS:1000478', ('The LC/MSD VL ion trap is part of the family of Agilent ion ' 'trap mass spectrometers. It has ESI, APCI and APPI ion ' 'sources and is a useful ion trap when the amount of sample ' 'is not the limiting factor.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6220 Time-of-Flight LC/MS', 'MS:1000675', ('The 6220 Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer. This time of flight mass ' 'spectrometer has a m/z range of 50-12000, mass accuracy of ' 'less than 2 ppm and resolution greater than 13,000 at m/z ' '2722. It has multiple ion sources and can be used with ' 'multimode ion sources.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6510 Quadrupole Time-of-Flight LC/MS', 'MS:1000676', ('The 6510 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer. This time of flight mass ' 'spectrometer has a m/z range of 50-12000, mass accuracy of ' 'less than 2 ppm and resolution greater than 13,000 at m/z ' '2722. It has multiple ion sources and can be used with ' 'multimode ion sources.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6520A Quadrupole Time-of-Flight LC/MS', 'MS:1000677', ('The 6520A Quadrupole Time-of-Flight LC/MS is a Agilent ' 'liquid chromatography instrument combined with a Agilent ' 'time of flight mass spectrometer. This time of flight mass ' 'spectrometer has a m/z range of 50-12000, mass accuracy of ' 'less than 2 ppm and resolution greater than 26,000 at m/z ' '2722. It has multiple ion sources and can be used with ' 'multimode ion sources.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6470A Triple Quadrupole LC/MS', 'MS:1000935', ('The 6470A Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6470B Triple Quadrupole LC/MS', 'MS:1000936', ('The 6470B Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6495C Triple Quadrupole LC/MS', 'MS:1000937', ('The 6495C Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6420 Triple Quadrupole LC/MS', 'MS:1002444', ('The 6420 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6460 Triple Quadrupole LC/MS', 'MS:1002445', ('The 6460 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer. It is similar to the 6420 but ' 'adds Agilent Jet Stream (AJS) technology to increase ' 'sensitivity.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6490 Triple Quadrupole LC/MS', 'MS:1002446', ('The 6490 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer. It is similar to the 6420 but ' 'adds the Agilent iFunnel technology to increase sensitivity.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6550 iFunnel Q-TOF LC/MS', 'MS:1002783', ('The 6550 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6550A iFunnel Q-TOF LC/MS', 'MS:1002784', ('The 6550A Quadrupole Time-of-Flight LC/MS is a Agilent ' 'liquid chromatography instrument combined with a Agilent ' 'time of flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6520B Q-TOF LC/MS', 'MS:1002785', ('The 6520B Quadrupole Time-of-Flight LC/MS is a Agilent ' 'liquid chromatography instrument combined with a Agilent ' 'time of flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6530A Q-TOF LC/MS', 'MS:1002786', ('The 6530A Quadrupole Time-of-Flight LC/MS is a Agilent ' 'liquid chromatography instrument combined with a Agilent ' 'time of flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6530B Q-TOF LC/MS', 'MS:1002787', ('The 6530B Quadrupole Time-of-Flight LC/MS is a Agilent ' 'liquid chromatography instrument combined with a Agilent ' 'time of flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6538 Q-TOF LC/MS', 'MS:1002788', ('The 6538 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6540 Q-TOF LC/MS', 'MS:1002789', ('The 6540 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6542 Q-TOF LC/MS', 'MS:1002790', ('The 6542 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6545 Q-TOF LC/MS', 'MS:1002791', ('The 6545 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6560 Q-TOF LC/MS', 'MS:1002792', ('The 6560 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6570 Q-TOF LC/MS', 'MS:1002793', ('The 6570 Quadrupole Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6120B Quadrupole LC/MS', 'MS:1002794', ('The 6120B Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a single quadrupole ' 'mass spectrometer from the 6100 Series of Agilent mass ' 'spectrometers.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6150 Quadrupole LC/MS', 'MS:1002795', ('The 6150 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a single quadrupole ' 'mass spectrometer from the 6100 Series of Agilent mass ' 'spectrometers.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6224 Time-of-Flight LC/MS', 'MS:1002796', ('The 6224 Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6230A Time-of-Flight LC/MS', 'MS:1002797', ('The 6230A Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6230B Time-of-Flight LC/MS', 'MS:1002798', ('The 6230B Time-of-Flight LC/MS is a Agilent liquid ' 'chromatography instrument combined with a Agilent time of ' 'flight mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6430 Triple Quadrupole LC/MS', 'MS:1002799', ('The 6430 Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6495A Triple Quadrupole LC/MS', 'MS:1002800', ('The 6495A Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('6495B Triple Quadrupole LC/MS', 'MS:1002801', ('The 6495B Quadrupole LC/MS system is a Agilent liquid ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('7000A Triple Quadrupole GC/MS', 'MS:1002802', ('The 7000A Quadrupole GC/MS system is a Agilent gas ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('7000B Triple Quadrupole GC/MS', 'MS:1002803', ('The 7000B Quadrupole GC/MS system is a Agilent gas ' 'chromatography instrument combined with a Agilent triple ' 'quadrupole mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('7800 Quadrupole ICP-MS', 'MS:1002804', ('The 7800 Quadrupole ICP-MS system is a Agilent inductively ' 'couple plasma instrument combined with a Agilent quadrupole ' 'mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('8800 Triple Quadrupole ICP-MS', 'MS:1002805', ('The 8800 Quadrupole ICP-MS system is a Agilent inductively ' 'couple plasma instrument combined with a Agilent quadrupole ' 'mass spectrometer.'), 'instrument model', ['Agilent instrument model', 'instrument model']), InstrumentModel('4700 Proteomics Analyzer', 'MS:1000140', ('Applied Biosystems/MDS SCIEX 4700 Proteomics Analyzer MS.'), 'instrument model', ['Applied Biosystems instrument model', 'instrument model']), InstrumentModel('Voyager-DE PRO', 'MS:1000203', ('Applied Biosystems/MDS SCIEX Voyager-DE PRO MS.'), 'instrument model', ['Applied Biosystems instrument model', 'instrument model']), InstrumentModel('Voyager-DE STR', 'MS:1000204', ('Applied Biosystems/MDS SCIEX Voyager-DE STR MS.'), 'instrument model', ['Applied Biosystems instrument model', 'instrument model']), InstrumentModel('4800 Proteomics Analyzer', 'MS:1000658', ('Applied Biosystems|MDS SCIEX 4800 Proteomics Analyzer.'), 'instrument model', ['Applied Biosystems instrument model', 'instrument model']), InstrumentModel('Pegasus HRT', 'MS:1001801', ('LECO high resolution time-of-flight GC mass spectrometer.'), 'instrument model', ['LECO instrument model', 'instrument model']), InstrumentModel('Citius HRT', 'MS:1001802', ('LECO high resolution time-of-flight LC mass spectrometer.'), 'instrument model', ['LECO instrument model', 'instrument model']), InstrumentModel('Pegasus', 'MS:1001803', ('LECO GC time-of-flight mass spectrometer.'), 'instrument model', ['LECO instrument model', 'instrument model']), InstrumentModel('TruTOF', 'MS:1001804', ('LECO bench-top GC time-of-flight mass spectrometer.'), 'instrument model', ['LECO instrument model', 'instrument model']), InstrumentModel('Pegasus 4D', 'MS:1001945', ('LECO nominal mass resolution time-of-flight GCxGC mass ' 'spectrometer.'), 'instrument model', ['LECO instrument model', 'instrument model']), InstrumentModel('Pegasus III', 'MS:1002278', ('LECO nominal mass resolution time-of-flight GC mass ' 'spectrometer.'), 'instrument model', ['LECO instrument model', 'instrument model']), InstrumentModel('Pegasus BT', 'MS:1002719', ('LECO bench-top GC time-of-flight mass spectrometer.'), 'instrument model', ['LECO instrument model', 'instrument model']), InstrumentModel('HCT', 'MS:1000160', ("Bruker Daltonics' HCT: ESI Q-TOF, Nanospray, APCI, APPI."), 'instrument model', ['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('HCTplus', 'MS:1000161', ("Bruker Daltonics' HCTplus: ESI Q-TOF, Nanospray, APCI, APPI."), 'instrument model', ['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('HCTultra', 'MS:1000698', ("Bruker Daltonics' HCTultra: ESI TOF, Nanospray, APCI, APPI."), 'instrument model', ['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('HCTultra PTM', 'MS:1000699', ("Bruker Daltonics' HCTultra PTM: ESI TOF, Nanospray, APCI, " 'APPI, PTR.'), 'instrument model', ['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('HCTultra ETD II', 'MS:1000700', ("Bruker Daltonics' HCTultra ETD II: ESI Q-TOF, Nanospray, " 'APCI, APPI, ETD.'), 'instrument model', ['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('esquire 4000', 'MS:1000156', ("Bruker Daltonics' esquire 4000: linear ion trap, ESI, MALDI, " 'Nanospray, APCI, APPI.'), 'instrument model', ['Bruker Daltonics esquire series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('esquire 6000', 'MS:1000157', ("Bruker Daltonics' esquire 6000: linear ion trap, ESI, MALDI, " 'Nanospray, APCI, APPI.'), 'instrument model', ['Bruker Daltonics esquire series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('autoflex II', 'MS:1000148', ("Bruker Daltonics' autoflex II: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('autoflex TOF/TOF', 'MS:1000149', ("Bruker Daltonics' autoflex TOF/TOF MS: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('microflex', 'MS:1000177', ("Bruker Daltonics' microflex: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('OmniFlex', 'MS:1000183', ("Bruker Daltonics' OmniFlex: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('ultraflex', 'MS:1000201', ("Bruker Daltonics' ultraflex: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('ultraflex TOF/TOF', 'MS:1000202', ("Bruker Daltonics' ultraflex TOF/TOF: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('autoflex III smartbeam', 'MS:1000696', ("Bruker Daltonics' autoflex III smartbeam: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('microflex LT', 'MS:1000701', ("Bruker Daltonics' microflex LT: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('ultraflex III TOF/TOF', 'MS:1000705', ("Bruker Daltonics' ultraflex III TOF/TOF: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('microflex LRF', 'MS:1001543', ("Bruker Daltonics' microflex LRF: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('ultrafleXtreme', 'MS:1001544', ("Bruker Daltonics' ultrafleXtreme: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('microflex II', 'MS:1001550', ("Bruker Daltonics' microflex II: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('autoflex II TOF/TOF', 'MS:1001553', ("Bruker Daltonics' autoflex II TOF/TOF: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('autoflex III TOF/TOF smartbeam', 'MS:1001554', ("Bruker Daltonics' autoflex III TOF/TOF smartbeam: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('autoflex', 'MS:1001555', ("Bruker Daltonics' autoflex: MALDI TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('rapifleX', 'MS:1003122', ("Bruker Daltonics' rapiflex: MALDI TOF/TOF."), 'instrument model', ['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('BioTOF II', 'MS:1000151', ("Bruker Daltonics' BioTOF II: ESI TOF."), 'instrument model', ['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('BioTOF-Q', 'MS:1000152', ("Bruker Daltonics' BioTOF-Q: ESI Q-TOF."), 'instrument model', ['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('BioTOF', 'MS:1001537', ("Bruker Daltonics' BioTOF: ESI TOF."), 'instrument model', ['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('BioTOF III', 'MS:1001538', ("Bruker Daltonics' BioTOF III: ESI TOF."), 'instrument model', ['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('UltroTOF-Q', 'MS:1001539', ("Bruker Daltonics' UltroTOF-Q: ESI Q-TOF (MALDI optional)."), 'instrument model', ['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('microTOF LC', 'MS:1000178', ("Bruker Daltonics' microTOF LC: ESI TOF, Nanospray, APCI, " 'APPI.'), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('micrOTOF', 'MS:1000702', ("Bruker Daltonics' micrOTOF: ESI TOF, APCI, APPI."), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('micrOTOF-Q', 'MS:1000703', ("Bruker Daltonics' micrOTOF-Q: ESI Q-TOF, Nanospray, APCI, " 'APPI.'), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('micrOTOF-Q II', 'MS:1000704', ("Bruker Daltonics' micrOTOF-Q II: ESI Q-TOF, Nanospray, APCI, " 'APPI.'), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('micrOTOF II', 'MS:1001540', ("Bruker Daltonics' micrOTOF II: ESI TOF, Nanospray, APCI, " 'APPI.'), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('impact', 'MS:1002077', ("Bruker Daltonics' impact: ESI Q-TOF, Nanospray, APCI, APPI, " 'GC-APCI, CaptiveSpray.'), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('compact', 'MS:1002280', ("Bruker Daltonics' compact: ESI Q-TOF, Nanospray, APCI, APPI, " 'GC-APCI, CaptiveSpray.'), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('micrOTOF-Q III', 'MS:1002299', ("Bruker Daltonics' micrOTOF-Q III: ESI Q-TOF, Nanospray, " 'APCI, APPI, GC-APCI, CaptiveSpray.'), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('impact II', 'MS:1002666', ("Bruker Daltonics' impact II."), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('impact HD', 'MS:1002667', ("Bruker Daltonics' impact HD."), 'instrument model', ['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('amaZon ETD', 'MS:1001542', ("Bruker Daltonics' amaZon ETD: ESI quadrupole ion trap, " 'Nanospray, APCI, APPI, ETD, PTR.'), 'instrument model', ['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('amaZon X', 'MS:1001546', ("Bruker Daltonics' amaZon X: ESI quadrupole ion trap, APCI, " 'APPI, ETD, PTR.'), 'instrument model', ['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('amaZon Speed ETD', 'MS:1002300', ("Bruker Daltonics' amaZon Speed ETD: ESI quadrupole ion trap, " 'Nanospray, APCI, APPI, ETD, PTR, GC-APCI, CaptiveSpray.'), 'instrument model', ['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('amaZon Speed', 'MS:1002301', ("Bruker Daltonics' amaZon ETD: ESI quadrupole ion trap, " 'Nanospray, APCI, APPI, GC-APCI, CaptiveSpray.'), 'instrument model', ['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('maXis', 'MS:1001541', ("Bruker Daltonics' maXis: ESI Q-TOF, Nanospray, APCI, APPI."), 'instrument model', ['Bruker Daltonics maXis series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('maXis 4G', 'MS:1002279', ("Bruker Daltonics' maXis 4G: ESI Q-TOF, Nanospray, APCI, " 'APPI, GC-APCI, CaptiveSpray.'), 'instrument model', ['Bruker Daltonics maXis series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('maXis II', 'MS:1003004', ("Bruker Daltonics' maXis II."), 'instrument model', ['Bruker Daltonics maXis series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('solariX', 'MS:1001549', ("Bruker Daltonics' solariX: ESI, MALDI, Qh-FT_ICR."), 'instrument model', ['Bruker Daltonics solarix series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('apex IV', 'MS:1000141', ("Bruker Daltonics' apex IV: ESI, MALDI, Nanospray, APCI, " 'APPI, Qh-FT_ICR.'), 'instrument model', ['Bruker Daltonics apex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('apex Q', 'MS:1000142', ("Bruker Daltonics' apex Q: ESI, MALDI, Nanospray, APCI, APPI, " 'Qh-FT_ICR.'), 'instrument model', ['Bruker Daltonics apex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('apex ultra', 'MS:1000695', ("Bruker Daltonics' apex ultra: ESI, MALDI, Nanospray, APCI, " 'APPI, Qh-FT_ICR.'), 'instrument model', ['Bruker Daltonics apex series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('SCION SQ', 'MS:1002295', ("Bruker Daltonics' SCION SQ: GC-single quadrupole."), 'instrument model', ['Bruker Daltonics SCION series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('SCION TQ', 'MS:1002296', ("Bruker Daltonics' SCION TQ: GC-triple quadrupole."), 'instrument model', ['Bruker Daltonics SCION series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('EVOQ Elite', 'MS:1002297', ("Bruker Daltonics' EVOQ Elite: LC-triple quadrupole."), 'instrument model', ['Bruker Daltonics EVOQ series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('EVOQ Qube', 'MS:1002298', ("Bruker Daltonics' EVOQ Qube: LC-triple quadrupole."), 'instrument model', ['Bruker Daltonics EVOQ series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('timsTOF Pro', 'MS:1003005', ("Bruker Daltonics' timsTOF Pro."), 'instrument model', ['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('timsTOF fleX', 'MS:1003124', ("Bruker Daltonics' timsTOF fleX"), 'instrument model', ['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('timsTOF', 'MS:1003229', ("Bruker Daltonics' timsTOF."), 'instrument model', ['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('timsTOF Pro 2', 'MS:1003230', ("Bruker Daltonics' timsTOF Pro 2."), 'instrument model', ['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('timsTOF SCP', 'MS:1003231', ("Bruker Daltonics' timsTOF SCP."), 'instrument model', ['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']), InstrumentModel('AXIMA CFR MALDI-TOF', 'MS:1000607', ('Shimadzu Biotech AXIMA CFR MALDI-TOF MS.'), 'instrument model', ['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('AXIMA-QIT', 'MS:1000608', ('Shimadzu Biotech AXIMA-QIT MS.'), 'instrument model', ['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('AXIMA-CFR plus', 'MS:1000609', ('Shimadzu Biotech AXIMA-CFR plus MS.'), 'instrument model', ['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('AXIMA Performance MALDI-TOF/TOF', 'MS:1000610', ('Shimadzu Biotech AXIMA Performance MALDI-TOF/TOF MS.'), 'instrument model', ['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('AXIMA Confidence MALDI-TOF', 'MS:1000611', ('Shimadzu Biotech AXIMA Confidence MALDI-TOF (curved field ' 'reflectron) MS.'), 'instrument model', ['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('AXIMA Assurance Linear MALDI-TOF', 'MS:1000612', ('Shimadzu Biotech AXIMA Assurance Linear MALDI-TOF MS.'), 'instrument model', ['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('Shimadzu MALDI-7090', 'MS:1002382', ('Shimadzu MALDI-7090: MALDI-TOF-TOF.'), 'instrument model', ['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-IT-TOF', 'MS:1000604', ('Shimadzu Scientific Instruments LCMS-IT-TOF MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-2010EV', 'MS:1000605', ('Shimadzu Scientific Instruments LCMS-2010EV MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-2010A', 'MS:1000606', ('Shimadzu Scientific Instruments LCMS-2010A MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-9030', 'MS:1002998', ('Shimadzu Scientific Instruments LCMS-9030 Q-TOF MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-8060', 'MS:1002999', ('Shimadzu Scientific Instruments LCMS-8060 MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-8050', 'MS:1003000', ('Shimadzu Scientific Instruments LCMS-8050 MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-8045', 'MS:1003001', ('Shimadzu Scientific Instruments LCMS-8045 MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-8040', 'MS:1003002', ('Shimadzu Scientific Instruments LCMS-8040 MS.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('LCMS-2020', 'MS:1003003', ('Shimadzu Scientific Instruments LCMS-2020.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('GCMS-QP2010SE', 'MS:1003152', ('Shimadzu Scientific Instruments GCMS-QP2010SE.'), 'instrument model', ['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']), InstrumentModel('DELTA plusAdvantage', 'MS:1000153', ('ThermoFinnigan DELTA plusAdvantage MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('DELTAplusXP', 'MS:1000154', ('ThermoFinnigan DELTAplusXP MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LCQ Advantage', 'MS:1000167', ('ThermoFinnigan LCQ Advantage MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LCQ Classic', 'MS:1000168', ('ThermoFinnigan LCQ Classic MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LCQ Deca XP Plus', 'MS:1000169', ('ThermoFinnigan LCQ Deca XP Plus MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('neptune', 'MS:1000179', ('ThermoFinnigan NEPTUNE MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('PolarisQ', 'MS:1000185', ('ThermoFinnigan PolarisQ MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Surveyor MSQ', 'MS:1000193', ('ThermoFinnigan Surveyor MSQ MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TEMPUS TOF', 'MS:1000196', ('ThermoFinnigan TEMPUS TOF MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TRACE DSQ', 'MS:1000197', ('ThermoFinnigan TRACE DSQ MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TRITON', 'MS:1000198', ('ThermoFinnigan TRITON MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Quantum', 'MS:1000199', ('ThermoFinnigan TSQ Quantum MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LCQ Deca', 'MS:1000554', ('ThermoFinnigan LCQ Deca.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('GC Quantum', 'MS:1000558', ('GC Quantum.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LCQ Fleet', 'MS:1000578', ('LCQ Fleet.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('DSQ', 'MS:1000634', ('ThermoFinnigan DSQ GC-MS.'), 'instrument model', ['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('MAT253', 'MS:1000172', ('ThermoFinnigan MAT253 MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('MAT900XP', 'MS:1000173', ('ThermoFinnigan MAT900XP MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('MAT900XP Trap', 'MS:1000174', ('ThermoFinnigan MAT900XP Trap MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('MAT95XP', 'MS:1000175', ('ThermoFinnigan MAT95XP MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('MAT95XP Trap', 'MS:1000176', ('ThermoFinnigan MAT95XP Trap MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('SSQ 7000', 'MS:1000748', ('ThermoFinnigan SSQ 7000 MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ 7000', 'MS:1000749', ('ThermoFinnigan TSQ 7000 MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ', 'MS:1000750', ('ThermoFinnigan TSQ MS.'), 'instrument model', ['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ', 'MS:1000447', ('Finnigan LTQ MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ FT', 'MS:1000448', ('Finnigan LTQ FT MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap', 'MS:1000449', ('Finnigan LTQ Orbitrap MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LXQ', 'MS:1000450', ('Finnigan LXQ MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap Discovery', 'MS:1000555', ('LTQ Orbitrap Discovery.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap XL', 'MS:1000556', ('LTQ Orbitrap XL.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ FT Ultra', 'MS:1000557', ('LTQ FT Ultra.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Surveyor PDA', 'MS:1000622', ('Surveyor PDA.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Accela PDA', 'MS:1000623', ('Accela PDA.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('ITQ 700', 'MS:1000635', ('Thermo Scientific ITQ 700 GC-MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('ITQ 900', 'MS:1000636', ('Thermo Scientific ITQ 900 GC-MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('ITQ 1100', 'MS:1000637', ('Thermo Scientific ITQ 1100 GC-MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ XL ETD', 'MS:1000638', ('Thermo Scientific LTQ XL MS with ETD.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap XL ETD', 'MS:1000639', ('Thermo Scientific LTQ Orbitrap XL MS with ETD.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('DFS', 'MS:1000640', ('Thermo Scientific DFS HR GC-MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('DSQ II', 'MS:1000641', ('Thermo Scientific DSQ II GC-MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('MALDI LTQ XL', 'MS:1000642', ('Thermo Scientific MALDI LTQ XL MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('MALDI LTQ Orbitrap', 'MS:1000643', ('Thermo Scientific MALDI LTQ Orbitrap MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Quantum Access', 'MS:1000644', ('Thermo Scientific TSQ Quantum Access MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Element XR', 'MS:1000645', ('Thermo Scientific Element XR HR-ICP-MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Element 2', 'MS:1000646', ('Thermo Scientific Element 2 HR-ICP-MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Element GD', 'MS:1000647', ('Thermo Scientific Element GD Glow Discharge MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('GC IsoLink', 'MS:1000648', ('Thermo Scientific GC IsoLink Isotope Ratio MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Exactive', 'MS:1000649', ('Thermo Scientific Exactive MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Quantum Ultra AM', 'MS:1000743', ('Thermo Scientific TSQ Quantum Ultra AM.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Quantum Ultra', 'MS:1000751', ('Thermo Scientific TSQ Quantum Ultra.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ XL', 'MS:1000854', ('Thermo Scientific LTQ XL MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Velos', 'MS:1000855', ('Thermo Scientific LTQ Velos MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Velos ETD', 'MS:1000856', ('Thermo Scientific LTQ Velos MS with ETD.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Vantage', 'MS:1001510', ('TSQ Vantage.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap Velos', 'MS:1001742', ('Finnigan LTQ Orbitrap Velos MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('ISQ', 'MS:1001908', ('Thermo Scientific ISQ single quadrupole MS with the ' 'ExtractraBrite source.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Velos Plus', 'MS:1001909', ('Thermo Scientific second generation Velos.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap Elite', 'MS:1001910', ('Thermo Scientific LTQ Orbitrap Elite, often just referred to ' 'as the Orbitrap Elite.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Q Exactive', 'MS:1001911', ('Thermo Scientific Q Exactive.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap Fusion', 'MS:1002416', ('Thermo Scientific Orbitrap Fusion.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap Fusion ETD', 'MS:1002417', ('Thermo Scientific Orbitrap Fusion with ETD.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Quantiva', 'MS:1002418', ('Thermo Scientific TSQ Quantiva MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Endura', 'MS:1002419', ('Thermo Scientific TSQ Endura MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Q Exactive HF', 'MS:1002523', ('Thermo Scientific Q Exactive.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ 8000 Evo', 'MS:1002525', ('Thermo Scientific TSQ 8000 Evo MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Exactive Plus', 'MS:1002526', ('Thermo Scientific Exactive Plus MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Q Exactive Plus', 'MS:1002634', ('Thermo Scientific Q Exactive Plus.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap Fusion Lumos', 'MS:1002732', ('Thermo Scientific Orbitrap Fusion Lumos mass spectrometer ' 'with Tribrid architecture consisting of quadrupole mass ' 'filter, linear ion trap and Orbitrap mass analyzers.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap Classic', 'MS:1002835', ('Thermo Fisher Scientific LTQ Orbitrap Classic.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Altis', 'MS:1002874', ('Thermo Scientific TSQ Altis Triple Quadrupole MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ Quantis', 'MS:1002875', ('Thermo Scientific TSQ Quantis Triple Quadrupole MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('TSQ 9000', 'MS:1002876', ('Thermo Scientific TSQ 9000 Triple Quadrupole MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Q Exactive HF-X', 'MS:1002877', ('Thermo Scientific Q Exactive HF-X Hybrid Quadrupole Orbitrap ' 'MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap Exploris 480', 'MS:1003028', ('Thermo Scientific Orbitrap Exploris 480 Quadrupole Orbitrap ' 'MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap Eclipse', 'MS:1003029', ('Thermo Scientific Orbitrap Eclipse mass spectrometer with ' 'Tribrid architecture consisting of quadrupole mass filter, ' 'linear ion trap and Orbitrap mass analyzers.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap Exploris 240', 'MS:1003094', ('Thermo Scientific Orbitrap Exploris 240 Quadrupole Orbitrap ' 'MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap Exploris 120', 'MS:1003095', ('Thermo Scientific Orbitrap Exploris 120 Quadrupole Orbitrap ' 'MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('LTQ Orbitrap Velos Pro', 'MS:1003096', ('Thermo Scientific LTQ Orbitrap Velos Pro, often just ' 'referred to as the Orbitrap Velos Pro.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Orbitrap ID-X', 'MS:1003112', ('Thermo Scientific Orbitrap ID-X mass spectrometer with ' 'Tribrid architecture consisting of quadrupole mass filter, ' 'linear ion trap and Orbitrap mass analyzers.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('Q Exactive UHMR', 'MS:1003245', ('Thermo Scientific Q Exactive UHMR (Ultra High Mass Range) ' 'Hybrid Quadrupole Orbitrap MS.'), 'instrument model', ['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']), InstrumentModel('explorer', 'MS:1000158', ('IonSpec Explorer MS.'), 'instrument model', ['IonSpec instrument model', 'Varian instrument model', 'instrument model']), InstrumentModel('HiRes ESI', 'MS:1000162', ('IonSpec HiResESI MS.'), 'instrument model', ['IonSpec instrument model', 'Varian instrument model', 'instrument model']), InstrumentModel('HiRes MALDI', 'MS:1000163', ('IonSpec HiResMALDI MS.'), 'instrument model', ['IonSpec instrument model', 'Varian instrument model', 'instrument model']), InstrumentModel('OMEGA', 'MS:1000181', ('IonSpec OMEGA MS.'), 'instrument model', ['IonSpec instrument model', 'Varian instrument model', 'instrument model']), InstrumentModel('OMEGA-2001', 'MS:1000182', ('IonSpec OMEGA-2001 MS.'), 'instrument model', ['IonSpec instrument model', 'Varian instrument model', 'instrument model']), InstrumentModel('ultima', 'MS:1000200', ('IonSpec Ultima MS.'), 'instrument model', ['IonSpec instrument model', 'Varian instrument model', 'instrument model']), ]) # [[[end]]]
[docs]class ComponentGroup(object): """Represent a collection of :class:`Component` objects which are part of a single instrument subsystem. Attributes ---------- type: str The name of the instrument subsystem members: list The components contained order: int The position of this group in the sequence of steps that analytes take when passing through the instrument. """ def __init__(self, type, members, order): self.type = type self.members = list(members) self.order = int(order) def __repr__(self): t = "{s.__class__.__name__}({s.type!r}, {s.members}, order={s.order})" return t.format(s=self) def __getitem__(self, i): return self.members[i] def __setitem__(self, i, v): self.members[i] = v def add(self, v): self.members.append(v) def __len__(self): return len(self.members)
[docs]class InstrumentInformation(object): """Describes a single configuration of an instrument for acquiring spectra. Parameters ---------- id: object The within-run unique identifier of this configuration. May be an integer or string groups: :class:`list` of :class:`ComponentGroup` The component groups, sorted by :attr:`ComponentGroup.order`, in this configuraton analyzers: list A convenience list for storing the :class:`Component` objects which are ``analyzer``s """ id: Union[str, int] groups: List[ComponentGroup] analyzer_types: List[Component] model: str serial_number: str name: str software: Software def __init__(self, id=None, groups=None, model=None, serial_number=None, name=None, software=None): self.id = id or uid() self.groups = sorted(groups or [], key=lambda x: x.order) self.analyzers = [] self.model = model self.serial_number = serial_number self.name = name self.software = software for group in self.groups: if group.type == 'analyzer': self.analyzers.extend(group) def __getitem__(self, i): return self.groups[i] def __len__(self): return len(self.groups) def __repr__(self): return "{self.__class__.__name__}({self.id!r}, {self.groups})".format( self=self)
__all__ = [ "InstrumentInformation", "ComponentGroup", "Component", "all_components_by_name", "ionization_types", "detector_types", "analyzer_types", "inlet_types", "component" ]