from __future__ import print_function
from typing import List, Union
from ms_deisotope.data_source.metadata.software import Software
from ms_deisotope.utils import uid
from .cv import Term, TermSet, render_list
[docs]class Component(Term):
"""Describes a named component of a mass spectrometer, either
using a controlled-vocabulary term or user-defined name.
A :class:`Component` is equal to its name and its controlled
vocabulary identifier.
"""
pass
# [[[cog
# import cog
# from ms_deisotope.data_source.metadata.cv import render_list
# render_list('ionization type', term_cls_name="Component", writer=cog.out)
# ]]]
# CV Version: 4.1.95
ionization_types = TermSet([
Component('chemical ionization', 'MS:1000071',
('The formation of a new ion by the reaction of a neutral '
'species with an ion. The process may involve transfer of an '
'electron, a proton or other charged species between the '
'reactants. When a positive ion results from chemical '
'ionization the term may be used without qualification. When '
'a negative ion results the term negative ion chemical '
'ionization should be used. Note that this term is not '
'synonymous with chemi-ionization.'),
'ionization type',
['ionization type']),
Component('electrospray ionization', 'MS:1000073',
('A process in which ionized species in the gas phase are '
'produced from an analyte-containing solution via highly '
'charged fine droplets, by means of spraying the solution '
'from a narrow-bore needle tip at atmospheric pressure in the '
'presence of a high electric field. When a pressurized gas is '
'used to aid in the formation of a stable spray, the term '
'pneumatically assisted electrospray ionization is used. The '
'term ion spray is not recommended.'),
'ionization type',
['ionization type']),
Component('fast atom bombardment ionization', 'MS:1000074',
('The ionization of any species by the interaction of a '
'focused beam of neutral atoms having a translational energy '
'of several thousand eV with a sample that is typically '
'dissolved in a solvent matrix. See also secondary '
'ionization.'),
'ionization type',
['ionization type']),
Component('multiphoton ionization', 'MS:1000227',
('Photoionization of an atom or molecule in which in two or '
'more photons are absorbed.'),
'ionization type',
['ionization type']),
Component('atmospheric pressure ionization', 'MS:1000240',
('Any ionization process in which ions are formed in the gas '
'phase at atmospheric pressure.'),
'ionization type',
['ionization type']),
Component('desorption ionization', 'MS:1000247',
('The formation of ions from a solid or liquid material after '
'the rapid vaporization of that sample.'),
'ionization type',
['ionization type']),
Component('flowing afterglow', 'MS:1000255',
('An ion source immersed in a flow of helium or other inert '
'buffer gas that carries the ions through a meter-long '
'reactor at pressures around 100 Pa.'),
'ionization type',
['ionization type']),
Component('field ionization', 'MS:1000258',
('The removal of electrons from any species by interaction '
'with a high electric field.'),
'ionization type',
['ionization type']),
Component('glow discharge ionization', 'MS:1000259',
('The formation of ions in the gas phase and from solid '
'samples at the cathode by application of a voltage to a low '
'pressure gas.'),
'ionization type',
['ionization type']),
Component('Negative Ion chemical ionization', 'MS:1000271',
('Chemical ionization that results in the formation of '
'negative ions.'),
'ionization type',
['ionization type']),
Component('neutralization reionization mass spectrometry', 'MS:1000272',
('With this technique, m/z selected ions form neutrals by '
'charge transfer to a collision gas or by dissociation. The '
'neutrals are separated from the remaining ions and ionized '
'in collisions with a second gas. This method is used to '
'investigate reaction intermediates and other unstable '
'species.'),
'ionization type',
['ionization type']),
Component('photoionization', 'MS:1000273',
('The ionization of an atom or molecule by a photon, written M '
'+ h? ? M^+ + e. The term photon impact is not recommended.'),
'ionization type',
['ionization type']),
Component('pyrolysis mass spectrometry', 'MS:1000274',
('A mass spectrometry technique in which the sample is heated '
'to the point of decomposition and the gaseous decomposition '
'products are introduced into the ion source.'),
'ionization type',
['ionization type']),
Component('resonance enhanced multiphoton ionization', 'MS:1000276',
('Multiphoton ionization in which the ionization cross section '
'is significantly enhanced because the energy of the incident '
'photons is resonant with an intermediate excited state of '
'the neutral species.'),
'ionization type',
['ionization type']),
Component('adiabatic ionization', 'MS:1000380',
('A process whereby an electron is removed from an atom, ion, '
'or molecule to produce an ion in its lowest energy state.'),
'ionization type',
['ionization type']),
Component('associative ionization', 'MS:1000381',
('An ionization process in which two excited atoms or '
'molecules react to form a single positive ion and an '
'electron.'),
'ionization type',
['ionization type']),
Component('autodetachment', 'MS:1000383',
('The formation of a neutral when a negative ion in a discrete '
'state with an energy greater than the detachment threshold '
'loses an electron spontaneously without further interaction '
'with an energy source.'),
'ionization type',
['ionization type']),
Component('autoionization', 'MS:1000384',
('The formation of an ion when an atom or molecule in a '
'discrete state with an energy greater than the ionization '
'threshold loses an electron spontaneously without further '
'interaction with an energy source.'),
'ionization type',
['ionization type']),
Component('charge exchange ionization', 'MS:1000385',
('The interaction of an ion with an atom or molecule in which '
'the charge on the ion is transferred to the neutral without '
'the dissociation of either. Synonymous with charge transfer '
'ionization.'),
'ionization type',
['ionization type']),
Component('chemi-ionization', 'MS:1000386',
('The reaction of a neutral molecule with an internally '
'excited molecule to form an ion. Note that this term is not '
'synonymous with chemical ionization.'),
'ionization type',
['ionization type']),
Component('dissociative ionization', 'MS:1000388',
('The reaction of a gas-phase molecule that results in its '
'decomposition to form products, one of which is an ion.'),
'ionization type',
['ionization type']),
Component('electron ionization', 'MS:1000389',
('The ionization of an atom or molecule by electrons that are '
'typically accelerated to energies between 50 and 150 eV. '
'Usually 70 eV electrons are used to produce positive ions. '
"The term 'electron impact' is not recommended."),
'ionization type',
['ionization type']),
Component('liquid secondary ionization', 'MS:1000395',
('The ionization of any species by the interaction of a '
'focused beam of ions with a sample that is dissolved in a '
'solvent matrix. See also fast atom bombardment and secondary '
'ionization.'),
'ionization type',
['ionization type']),
Component('penning ionization', 'MS:1000399',
('Ionization that occurs through the interaction of two or '
'more neutral gaseous species, at least one of which is '
'internally excited.'),
'ionization type',
['ionization type']),
Component('plasma desorption ionization', 'MS:1000400',
('The ionization of material in a solid sample by bombarding '
'it with ionic or neutral atoms formed as a result of the '
'fission of a suitable nuclide, typically 252Cf. Synonymous '
'with fission fragment ionization.'),
'ionization type',
['ionization type']),
Component('secondary ionization', 'MS:1000402',
('The process in which ions are ejected from a sample surface '
'as a result of bombardment by a primary beam of atoms or '
'ions.'),
'ionization type',
['ionization type']),
Component('soft ionization', 'MS:1000403',
('The formation of gas-phase ions without extensive '
'fragmentation.'),
'ionization type',
['ionization type']),
Component('spark ionization', 'MS:1000404',
('The formation of ions from a solid material by an '
'intermittent electrical discharge.'),
'ionization type',
['ionization type']),
Component('surface ionization', 'MS:1000406',
('The ionization of a neutral species when it interacts with a '
'solid surface with an appropriate work function and '
'temperature.'),
'ionization type',
['ionization type']),
Component('thermal ionization', 'MS:1000407',
('The ionization of a neutral species through contact with a '
'high temperature surface.'),
'ionization type',
['ionization type']),
Component('vertical ionization', 'MS:1000408',
('A process in which an electron is removed from or added to a '
'molecule without a change in the positions of the atoms. The '
'resulting ion is typically in an excited vibrational state.'),
'ionization type',
['ionization type']),
Component('fast ion bombardment', 'MS:1000446',
('The ionization of any species by the interaction of a '
'focused beam of ions having a translational energy of '
'several thousand eV with a solid sample.'),
'ionization type',
['ionization type']),
Component('paper spray ionization', 'MS:1003235',
('The ionization of analytes from a piece of paper by applying '
'a solvent and voltage.'),
'ionization type',
['ionization type']),
Component('proton transfer reaction', 'MS:1003248',
('Process to transfer a proton from a hydronium ion (H3O+) to '
'neutral analyte, leading to a protonated analyte, which '
'typically does not lead to fragmentation." '
'[DOI:10.1002/mas.20048'),
'ionization type',
['ionization type']),
Component('proton transfer charge reduction', 'MS:1003249',
('Process to transfer one or more protons from a multiply '
'charged cation (peptide or protein ion) to a proton acceptor '
'anion or neutral basic compound, thereby reducing the charge '
'of the original analyte.'),
'ionization type',
['ionization type']),
Component('microelectrospray', 'MS:1000397',
('Electrospray ionization at a solvent flow rate of 300-800 '
'nL/min where the flow is a result of a mechanical pump. See '
'nanoelectrospray.'),
'ionization type',
['electrospray ionization', 'ionization type']),
Component('nanoelectrospray', 'MS:1000398',
('Electrospray ionization at a flow rate less than ~25 nL/min. '
'Nanoelectrospray is synonymous with nanospray. The flow is '
'dependent on the potenial on the tip of the electrospray '
'needle and/or a gas presure to push the sample through the '
'needle. See also electrospray ionization and '
'microelectrospray.'),
'ionization type',
['electrospray ionization', 'ionization type']),
Component('atmospheric pressure chemical ionization', 'MS:1000070',
('Chemical ionization that takes place at atmospheric pressure '
'as opposed to the reduced pressure is normally used for '
'chemical ionization.'),
'ionization type',
['atmospheric pressure ionization', 'ionization type']),
Component('atmospheric pressure matrix-assisted laser desorption ionization', 'MS:1000239',
('Matrix-assisted laser desorption ionization in which the '
'sample target is at atmospheric pressure and the ions formed '
'by the pulsed laser are sampled through a small aperture '
'into the mass spectrometer.'),
'ionization type',
['atmospheric pressure ionization', 'ionization type']),
Component('atmospheric pressure photoionization', 'MS:1000382',
('Atmospheric pressure chemical ionization in which the '
'reactant ions are generated by photo-ionization.'),
'ionization type',
['atmospheric pressure ionization', 'ionization type']),
Component('desorption electrospray ionization', 'MS:1002011',
('Combination of electrospray and desorption ionization method '
'that ionizes gases, liquids and solids in open air under '
'atmospheric pressure." [DOI:10.1126/science.1104404'),
'ionization type',
['atmospheric pressure ionization', 'ionization type']),
Component('matrix-assisted laser desorption ionization', 'MS:1000075',
('The formation of gas-phase ions from molecules that are '
'present in a solid or solvent matrix that is irradiated with '
'a pulsed laser. See also laser desorption/ionization.'),
'ionization type',
['desorption ionization', 'ionization type']),
Component('field desorption', 'MS:1000257',
('The formation of gas-phase ions from a material deposited on '
'a solid surface in the presence of a high electric field. '
'Because this process may encompass ionization by field '
'ionization or other mechanisms, it is not recommended as a '
'synonym for field desorption ionization.'),
'ionization type',
['desorption ionization', 'ionization type']),
Component('desorption/ionization on silicon', 'MS:1000387',
('The formation of ions by laser desorption ionization of a '
'sample deposited on a porous silicon surface.'),
'ionization type',
['desorption ionization', 'ionization type']),
Component('laser desorption ionization', 'MS:1000393',
('The formation of gas-phase ions by the interaction of a '
'pulsed laser with a solid or liquid material.'),
'ionization type',
['desorption ionization', 'ionization type']),
Component('surface-assisted laser desorption ionization', 'MS:1000405',
('The formation of gas-phase ions from molecules that are '
'deposited on a particular surface substrate that is '
'irradiated with a pulsed laser. See also matrix-assisted '
'laser desorption ionization.'),
'ionization type',
['desorption ionization', 'ionization type']),
Component('surface enhanced laser desorption ionization', 'MS:1000278',
('The formation of ionized species in the gas phase from '
'analytes deposited on a particular surface substrate which '
'is irradiated with a laser beam of which wavelength is '
'absorbed by the surface. See also desorption/ionization on '
'silicon and laser desorption/ionization.'),
'ionization type',
['surface ionization', 'ionization type']),
Component('surface enhanced neat desorption', 'MS:1000279',
('Matrix-assisted laser desorption ionization in which the '
'matrix is covalently linked to the target surface.'),
'ionization type',
['surface ionization', 'ionization type']),
])
# [[[end]]]
# [[[cog
# import cog
# from ms_deisotope.data_source.metadata.cv import render_list
# render_list('detector type', term_cls_name="Component", writer=cog.out)
# ]]]
# CV Version: 4.1.95
detector_types = TermSet([
Component('channeltron', 'MS:1000107',
('A horn-shaped (or cone-shaped) continuous dynode particle '
'multiplier. The ion strikes the inner surface of the device '
'and induces the production of secondary electrons that in '
'turn impinge on the inner surfaces to produce more secondary '
'electrons. This avalanche effect produces an increase in '
'signal in the final measured current pulse.'),
'detector type',
['detector type']),
Component('daly detector', 'MS:1000110',
('Detector consisting of a conversion dynode, scintillator and '
'photomultiplier. The metal knob at high potential emits '
'secondary electrons when ions impinge on the surface. The '
'secondary electrons are accelerated onto the scintillator '
'that produces light that is then detected by the '
'photomultiplier detector.'),
'detector type',
['detector type']),
Component('faraday cup', 'MS:1000112',
('A conducting cup or chamber that intercepts a charged '
'particle beam and is electrically connected to a current '
'measuring device.'),
'detector type',
['detector type']),
Component('multi-collector', 'MS:1000115',
('A detector system commonly used in inductively coupled '
'plasma mass spectrometers.'),
'detector type',
['detector type']),
Component('photomultiplier', 'MS:1000116',
('A detector for conversion of the ion/electron signal into '
'photon(s) which are then amplified and detected.'),
'detector type',
['detector type']),
Component('electron multiplier', 'MS:1000253',
('A device to amplify the current of a beam or packet of '
'charged particles or photons by incidence upon the surface '
'of an electrode to produce secondary electrons. The '
'secondary electrons are then accelerated to other electrodes '
'or parts of a continuous electrode to produce further '
'secondary electrons.'),
'detector type',
['detector type']),
Component('array detector', 'MS:1000345',
('Detector comprising several ion collection elements, '
'arranged in a line or grid where each element is an '
'individual detector.'),
'detector type',
['detector type']),
Component('conversion dynode', 'MS:1000346',
('A surface that is held at high potential such that ions '
'striking the surface produce electrons that are subsequently '
'detected.'),
'detector type',
['detector type']),
Component('dynode', 'MS:1000347',
('One of a series of electrodes in a photomultiplier tube. '
'Such an arrangement is able to amplify the current emitted '
'by the photocathode.'),
'detector type',
['detector type']),
Component('focal plane collector', 'MS:1000348',
('A detector for spatially disperse ion beams in which all '
'ions simultaneously impinge on the detector plane.'),
'detector type',
['detector type']),
Component('ion-to-photon detector', 'MS:1000349',
('A detector in which ions strike a conversion dynode to '
'produce electrons that in turn strike a phosphor and the '
'resulting photons are detected by a photomultiplier.'),
'detector type',
['detector type']),
Component('point collector', 'MS:1000350',
('A detector in which the ion beam is focused onto a point and '
'the individual ions arrive sequentially.'),
'detector type',
['detector type']),
Component('postacceleration detector', 'MS:1000351',
('A detector in which the charged particles are accelerated to '
'a high velocity and impinge on a conversion dynode, emitting '
'secondary electrons. The electrons are accelerated onto a '
'phosphor screen, which emits photons that are in turn '
'detected using a photomultiplier or other photon detector.'),
'detector type',
['detector type']),
Component('inductive detector', 'MS:1000624',
('Inductive detector.'),
'detector type',
['detector type']),
Component('fluorescence detector', 'MS:1002308',
('A detector using a fluorescent signal after excitation with '
'light.'),
'detector type',
['detector type']),
Component('electron multiplier tube', 'MS:1000111',
('A device to amplify the current of a beam or packet of '
'charged particles or photons by incidence upon the surface '
'of an electrode to produce secondary electrons.'),
'detector type',
['electron multiplier', 'detector type']),
Component('microchannel plate detector', 'MS:1000114',
('A thin plate that contains a closely spaced array of '
'channels that each act as a continuous dynode particle '
'multiplier. A charged particle, fast neutral particle, or '
'photon striking the plate causes a cascade of secondary '
'electrons that ultimately exits the opposite side of the '
'plate.'),
'detector type',
['array detector', 'detector type']),
Component('photodiode array detector', 'MS:1000621',
('An array detector used to record spectra in the ultraviolet '
'and visible region of light.'),
'detector type',
['array detector', 'detector type']),
Component('conversion dynode electron multiplier', 'MS:1000108',
('A surface that is held at high potential so that ions '
'striking the surface produce electrons that are subsequently '
'detected.'),
'detector type',
['conversion dynode', 'detector type']),
Component('conversion dynode photomultiplier', 'MS:1000109',
('A detector in which ions strike a conversion dynode to '
'produce electrons that in turn generate photons through a '
'phosphorescent screen that are detected by a '
'photomultiplier.'),
'detector type',
['conversion dynode', 'detector type']),
Component('focal plane array', 'MS:1000113',
('An array of detectors for spatially disperse ion beams in '
'which all ions simultaneously impinge on the detector plane.'),
'detector type',
['focal plane collector', 'detector type']),
Component('Acquity UPLC FLR', 'MS:1000819',
('Acquity UPLC Fluorescence Detector.'),
'detector type',
['Waters instrument model', 'fluorescence detector', 'instrument model', 'detector type']),
Component('Acquity UPLC PDA', 'MS:1000818',
('Acquity UPLC Photodiode Array Detector.'),
'detector type',
['Waters instrument model', 'photodiode array detector', 'instrument model', 'array detector', 'detector type']),
])
# [[[end]]]
# [[[cog
# import cog
# from ms_deisotope.data_source.metadata.cv import render_list
# render_list('mass analyzer type', 'analyzer_types', term_cls_name="Component", writer=cog.out)
# ]]]
# CV Version: 4.1.95
analyzer_types = TermSet([
Component('fourier transform ion cyclotron resonance mass spectrometer', 'MS:1000079',
('A mass spectrometer based on the principle of ion cyclotron '
'resonance in which an ion in a magnetic field moves in a '
'circular orbit at a frequency characteristic of its m/z '
'value. Ions are coherently excited to a larger radius orbit '
'using a pulse of radio frequency energy and their image '
'charge is detected on receiver plates as a time domain '
'signal. Fourier transformation of the time domain signal '
'results in a frequency domain signal which is converted to a '
'mass spectrum based in the inverse relationship between '
'frequency and m/z.'),
'mass analyzer type',
['mass analyzer type']),
Component('magnetic sector', 'MS:1000080',
('A device that produces a magnetic field perpendicular to a '
'charged particle beam that deflects the beam to an extent '
'that is proportional to the particle momentum per unit '
'charge. For a monoenergetic beam, the deflection is '
'proportional to m/z.'),
'mass analyzer type',
['mass analyzer type']),
Component('quadrupole', 'MS:1000081',
('A mass spectrometer that consists of four parallel rods '
'whose centers form the corners of a square and whose '
'opposing poles are connected. The voltage applied to the '
'rods is a superposition of a static potential and a '
'sinusoidal radio frequency potential. The motion of an ion '
'in the x and y dimensions is described by the Matthieu '
'equation whose solutions show that ions in a particular m/z '
'range can be transmitted along the z axis.'),
'mass analyzer type',
['mass analyzer type']),
Component('time-of-flight', 'MS:1000084',
('Instrument that separates ions by m/z in a field-free region '
'after acceleration to a fixed acceleration energy.'),
'mass analyzer type',
['mass analyzer type']),
Component('electrostatic energy analyzer', 'MS:1000254',
('A device consisting of conducting parallel plates, '
'concentric cylinders or concentric spheres that separates '
'charged particles according to their kinetic energy by means '
'of an electric field that is constant in time.'),
'mass analyzer type',
['mass analyzer type']),
Component('ion trap', 'MS:1000264',
('A device for spatially confining ions using electric and '
'magnetic fields alone or in combination.'),
'mass analyzer type',
['mass analyzer type']),
Component('stored waveform inverse fourier transform', 'MS:1000284',
('A technique to create excitation waveforms for ions in FT- '
'ICR mass spectrometer or Paul ion trap. An excitation '
'waveform in the time-domain is generated by taking the '
'inverse Fourier transform of an appropriate frequency-domain '
'programmed excitation spectrum, in which the resonance '
'frequencies of ions to be excited are included. This '
'technique may be used for selection of precursor ions in MS2 '
'experiments.'),
'mass analyzer type',
['mass analyzer type']),
Component('cyclotron', 'MS:1000288',
('A device that uses an oscillating electric field and '
'magnetic field to accelerate charged particles.'),
'mass analyzer type',
['mass analyzer type']),
Component('orbitrap', 'MS:1000484',
('An ion trapping device that consists of an outer barrel-like '
'electrode and a coaxial inner spindle-like electrode that '
'form an electrostatic field with quadro-logarithmic '
'potential distribution. The frequency of harmonic '
'oscillations of the orbitally trapped ions along the axis of '
'the electrostatic field is independent of the ion velocity '
'and is inversely proportional to the square root of m/z so '
'that the trap can be used as a mass analyzer.'),
'mass analyzer type',
['mass analyzer type']),
Component('quadrupole ion trap', 'MS:1000082',
('Quadrupole Ion Trap mass analyzer captures the ions in a '
'three dimensional ion trap and then selectively ejects them '
'by varying the RF and DC potentials.'),
'mass analyzer type',
['ion trap', 'mass analyzer type']),
Component('linear ion trap', 'MS:1000291',
('A two dimensional Paul ion trap in which ions are confined '
'in the axial dimension by means of an electric field at the '
'ends of the trap.'),
'mass analyzer type',
['ion trap', 'mass analyzer type']),
Component('axial ejection linear ion trap', 'MS:1000078',
('A linear ion trap mass spectrometer where ions are ejected '
'along the axis of the analyzer.'),
'mass analyzer type',
['linear ion trap', 'ion trap', 'mass analyzer type']),
Component('radial ejection linear ion trap', 'MS:1000083',
('A linear ion trap mass spectrometer where ions are ejected '
'along the radius of the analyzer.'),
'mass analyzer type',
['linear ion trap', 'ion trap', 'mass analyzer type']),
])
# [[[end]]]
# [[[cog
# import cog
# from ms_deisotope.data_source.metadata.cv import render_list
# render_list('inlet type', term_cls_name="Component", writer=cog.out)
# ]]]
# CV Version: 4.1.95
inlet_types = TermSet([
Component('continuous flow fast atom bombardment', 'MS:1000055',
('Fast atom bombardment ionization in which the analyte in '
'solution is entrained in a flowing liquid matrix.'),
'inlet type',
['inlet type']),
Component('direct inlet', 'MS:1000056',
('The sample is directly inserted into the ion source, usually '
'on the end of a heatable probe.'),
'inlet type',
['inlet type']),
Component('electrospray inlet', 'MS:1000057',
('Inlet used for introducing the liquid sample into an '
'electrospray ionization source.'),
'inlet type',
['inlet type']),
Component('flow injection analysis', 'MS:1000058',
('Sample is directly injected or infused into the ionization '
'source.'),
'inlet type',
['inlet type']),
Component('inductively coupled plasma', 'MS:1000059',
('A gas discharge ion source in which the energy to the plasma '
'is supplied by electromagnetic induction.'),
'inlet type',
['inlet type']),
Component('infusion', 'MS:1000060',
('The continuous flow of solution of a sample into the '
'ionization source.'),
'inlet type',
['inlet type']),
Component('jet separator', 'MS:1000061',
('A device that separates carrier gas from gaseous analyte '
'molecules on the basis of diffusivity.'),
'inlet type',
['inlet type']),
Component('membrane separator', 'MS:1000062',
('A device to separate carrier molecules from analyte '
'molecules on the basis of ease of diffusion across a '
'semipermeable membrane.'),
'inlet type',
['inlet type']),
Component('moving belt', 'MS:1000063',
('Continuous moving surface in the form of a belt which passes '
'through an ion source carrying analyte molecules.'),
'inlet type',
['inlet type']),
Component('moving wire', 'MS:1000064',
('Continuous moving surface in the form of a wire which passes '
'through an ion source carrying analyte molecules.'),
'inlet type',
['inlet type']),
Component('open split', 'MS:1000065',
('A division of flowing stream of liquid into two streams.'),
'inlet type',
['inlet type']),
Component('particle beam', 'MS:1000066',
('Method for generating ions from a solution of an analyte.'),
'inlet type',
['inlet type']),
Component('reservoir', 'MS:1000067',
('A sample inlet method involving a reservoir.'),
'inlet type',
['inlet type']),
Component('septum', 'MS:1000068',
('A disc composed of a flexible material that seals the '
'entrance to the reservoir. Can also be entrance to the '
'vacuum chamber.'),
'inlet type',
['inlet type']),
Component('thermospray inlet', 'MS:1000069',
('A method for generating gas phase ions from a solution of an '
'analyte by rapid heating of the sample.'),
'inlet type',
['inlet type']),
Component('direct insertion probe', 'MS:1000248',
('A device for introducing a solid or liquid sample into a '
'mass spectrometer ion source for desorption ionization.'),
'inlet type',
['inlet type']),
Component('direct liquid introduction', 'MS:1000249',
('The delivery of a liquid sample into a mass spectrometer for '
'spray or desorption ionization.'),
'inlet type',
['inlet type']),
Component('membrane inlet', 'MS:1000396',
('A semi-permeable membrane separator that permits the passage '
'of gas sample directly to the mass spectrometer ion source.'),
'inlet type',
['inlet type']),
Component('nanospray inlet', 'MS:1000485',
('Nanospray Inlet.'),
'inlet type',
['electrospray inlet', 'inlet type']),
])
# [[[end]]]
all_components = ionization_types + detector_types + analyzer_types + inlet_types
# more consistent alias
components = all_components
all_components_by_name = {c.name: c for c in all_components}
def component(name):
try:
return all_components_by_name[name]
except KeyError:
return Component(name, name, name, name, [name])
class InstrumentModel(Term):
"""Describes a named model of a mass spectrometer, either
using a controlled-vocabulary term or user-defined name.
A :class:`InstrumentModel` is equal to its name and its controlled
vocabulary identifier.
"""
pass
# [[[cog
# import cog
# from ms_deisotope.data_source.metadata.cv import render_list
# render_list('instrument model', term_cls_name="InstrumentModel", writer=cog.out)
# ]]]
# CV Version: 4.1.95
instrument_models = TermSet([
InstrumentModel('SCIEX instrument model', 'MS:1000121',
('The brand of instruments from the joint venture between '
'Applied Biosystems and MDS Analytical Technologies (formerly '
'MDS SCIEX). Previously branded as \\"Applied Biosystems|MDS '
'SCIEX\\".'),
'instrument model',
['instrument model']),
InstrumentModel('Bruker Daltonics instrument model', 'MS:1000122',
("Bruker Daltonics' instrument model."),
'instrument model',
['instrument model']),
InstrumentModel('Shimadzu instrument model', 'MS:1000124',
('Shimadzu corporation instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('Waters instrument model', 'MS:1000126',
('Waters Corporation instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('Thermo Fisher Scientific instrument model', 'MS:1000483',
('Thermo Fisher Scientific instrument model. The company has '
'gone through several names including Thermo Finnigan, Thermo '
'Scientific.'),
'instrument model',
['instrument model']),
InstrumentModel('Hitachi instrument model', 'MS:1000488',
('Hitachi instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('Varian instrument model', 'MS:1000489',
('Varian instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('Agilent instrument model', 'MS:1000490',
('Agilent instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('Dionex instrument model', 'MS:1000491',
('Dionex instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('Applied Biosystems instrument model', 'MS:1000495',
('Applied Biosystems instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('LECO instrument model', 'MS:1001800',
('LECO instrument model.'),
'instrument model',
['instrument model']),
InstrumentModel('4000 QTRAP', 'MS:1000139',
('Applied Biosystems/MDS SCIEX Q 4000 TRAP MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 150EX', 'MS:1000143',
('Applied Biosystems/MDS SCIEX API 150EX MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 150EX Prep', 'MS:1000144',
('Applied Biosystems/MDS SCIEX API 150EX Prep MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 2000', 'MS:1000145',
('Applied Biosystems/MDS SCIEX API 2000 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 3000', 'MS:1000146',
('Applied Biosystems/MDS SCIEX API 3000 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 4000', 'MS:1000147',
('Applied Biosystems/MDS SCIEX API 4000 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('proteomics solution 1', 'MS:1000186',
('Applied Biosystems/MDS SCIEX Proteomics Solution 1 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Q TRAP', 'MS:1000187',
('Applied Biosystems/MDS SCIEX Q TRAP MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QSTAR', 'MS:1000190',
('Applied Biosystems/MDS SCIEX QSTAR MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('SymBiot I', 'MS:1000194',
('Applied Biosystems/MDS SCIEX SymBiot I MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('SymBiot XVI', 'MS:1000195',
('Applied Biosystems/MDS SCIEX SymBiot XVI MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('3200 QTRAP', 'MS:1000651',
('SCIEX or Applied Biosystems|MDS SCIEX QTRAP 3200.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('4800 Plus MALDI TOF/TOF', 'MS:1000652',
('SCIEX or Applied Biosystems|MDS SCIEX 4800 Plus MALDI TOF- '
'TOF Analyzer.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 3200', 'MS:1000653',
('SCIEX or Applied Biosystems|MDS SCIEX API 3200 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 5000', 'MS:1000654',
('SCIEX or Applied Biosystems|MDS SCIEX API 5000 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QSTAR Elite', 'MS:1000655',
('SCIEX or Applied Biosystems|MDS SCIEX QSTAR Elite.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QSTAR Pulsar', 'MS:1000656',
('Applied Biosystems|MDS SCIEX QSTAR Pulsar.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QSTAR XL', 'MS:1000657',
('Applied Biosystems|MDS SCIEX QSTAR XL.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QTRAP 5500', 'MS:1000931',
('Applied Biosystems|MDS SCIEX QTRAP 5500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('TripleTOF 5600', 'MS:1000932',
('SCIEX TripleTOF 5600, a quadrupole - quadrupole - time-of- '
'flight mass spectrometer.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('5800 TOF/TOF', 'MS:1001482',
('SCIEX 5800 TOF-TOF Analyzer.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('TripleTOF 6600', 'MS:1002533',
('SCIEX TripleTOF 6600, a quadrupole - quadrupole - time-of- '
'flight mass spectrometer.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('2000 QTRAP', 'MS:1002577',
('SCIEX 2000 QTRAP.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('2500 QTRAP', 'MS:1002578',
('SCIEX 2500 QTRAP.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('3500 QTRAP', 'MS:1002579',
('SCIEX 3500 QTRAP.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QTRAP 4500', 'MS:1002580',
('SCIEX QTRAP 4500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QTRAP 6500', 'MS:1002581',
('SCIEX QTRAP 6500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('QTRAP 6500+', 'MS:1002582',
('SCIEX QTRAP 6500+.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('TripleTOF 4600', 'MS:1002583',
('SCIEX TripleTOF 4600 time-of-flight mass spectrometer.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('TripleTOF 5600+', 'MS:1002584',
('SCIEX TripleTOF 5600+ time-of-flight mass spectrometer.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 100', 'MS:1002585',
('Applied Biosystems/MDS SCIEX API 100 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 100LC', 'MS:1002586',
('Applied Biosystems/MDS SCIEX API 100LC MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 165', 'MS:1002587',
('Applied Biosystems/MDS SCIEX API 165 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 300', 'MS:1002588',
('Applied Biosystems/MDS SCIEX API 300 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 350', 'MS:1002589',
('Applied Biosystems/MDS SCIEX API 350 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('API 365', 'MS:1002590',
('Applied Biosystems/MDS SCIEX API 365 MS.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Triple Quad 3500', 'MS:1002591',
('SCIEX Triple Quad 3500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Triple Quad 4500', 'MS:1002592',
('SCIEX Triple Quad 4500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Triple Quad 5500', 'MS:1002593',
('SCIEX Triple Quad 5500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Triple Quad 6500', 'MS:1002594',
('SCIEX Triple Quad 6500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Triple Quad 6500+', 'MS:1002595',
('SCIEX Triple Quad 6500+.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('X500R QTOF', 'MS:1002674',
('SCIEX X500R QTOF, a quadrupole - quadrupole - time-of-flight '
'mass spectrometer.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Triple Quad 7500', 'MS:1003144',
('SCIEX Triple Quad 7500.'),
'instrument model',
['SCIEX instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics HCT Series', 'MS:1000697',
("Bruker Daltonics' HCT Series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics esquire series', 'MS:1001533',
("Bruker Daltonics' esquire series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics flex series', 'MS:1001534',
("Bruker Daltonics' flex series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics BioTOF series', 'MS:1001535',
("Bruker Daltonics' BioTOF series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics micrOTOF series', 'MS:1001536',
("Bruker Daltonics' micrOTOF series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics amaZon series', 'MS:1001545',
("Bruker Daltonics' amaZon series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics maXis series', 'MS:1001547',
("Bruker Daltonics' maXis series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics solarix series', 'MS:1001548',
("Bruker Daltonics' solarix: ESI quadrupole ion trap, APCI, "
'APPI, ETD, PTR.'),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics apex series', 'MS:1001556',
("Bruker Daltonics' apex series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics SCION series', 'MS:1002293',
("Bruker Daltonics' SCION series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics EVOQ series', 'MS:1002294',
("Bruker Daltonics' EVOQ series."),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Bruker Daltonics timsTOF series', 'MS:1003123',
('Bruker Daltonics timsTOF series'),
'instrument model',
['Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('Shimadzu MALDI-TOF instrument model', 'MS:1000602',
('Shimadzu MALDI-TOF instrument model.'),
'instrument model',
['Shimadzu instrument model', 'instrument model']),
InstrumentModel('Shimadzu Scientific Instruments instrument model', 'MS:1000603',
('Shimadzu Scientific Instruments instrument model.'),
'instrument model',
['Shimadzu instrument model', 'instrument model']),
InstrumentModel('Auto Spec Ultima NT', 'MS:1000150',
('Waters magnetic sector based AutoSpec Ultima NT MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('GCT', 'MS:1000159',
('Waters oa-ToF based GCT.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('IsoPrime', 'MS:1000164',
('Waters IsoPrime MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('IsoProbe', 'MS:1000165',
('Waters IsoProbe MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('IsoProbe T', 'MS:1000166',
('Waters IsoProbe T MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('M@LDI L', 'MS:1000170',
('Waters oa-ToF based MALDI L.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('M@LDI LR', 'MS:1000171',
('Waters oa-ToF based MALDI LR.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('NG-5400', 'MS:1000180',
('Waters NG-5400 MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Platform ICP', 'MS:1000184',
('Waters Platform ICP MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Q-Tof micro', 'MS:1000188',
('Waters oa-ToF based Q-Tof micro.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Q-Tof Ultima', 'MS:1000189',
('Waters oa-ToF based Q-Tof Ultima.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('quattro micro', 'MS:1000191',
('Waters (triple) quadrupole based micro.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Quattro Ultima', 'MS:1000192',
('Waters (triple) quadrupole based Ultima.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Q-Tof Premier', 'MS:1000632',
('Waters oa-ToF based Q-Tof Premier.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Acquity UPLC PDA', 'MS:1000818',
('Acquity UPLC Photodiode Array Detector.'),
'instrument model',
['Waters instrument model', 'photodiode array detector', 'instrument model', 'array detector', 'detector type']),
InstrumentModel('Acquity UPLC FLR', 'MS:1000819',
('Acquity UPLC Fluorescence Detector.'),
'instrument model',
['Waters instrument model', 'fluorescence detector', 'instrument model', 'detector type']),
InstrumentModel('ACQUITY UPLC', 'MS:1001761',
('Waters LC-system ACQUITY UPLC.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('ACQUITY UPLC H-Class', 'MS:1001762',
('Waters LC-system ACQUITY UPLC H-Class.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('ACQUITY UPLC H-Class Bio', 'MS:1001763',
('Waters LC-system ACQUITY UPLC H-Class Bio.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('ACQUITY UPLC I-Class', 'MS:1001764',
('Waters LC-system ACQUITY UPLC I-Class.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('ACQUITY UPLC Systems with 2D Technology', 'MS:1001765',
('Waters LC-system ACQUITY UPLC Systems with 2D Technology.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('nanoACQUITY UPLC', 'MS:1001766',
('Waters LC-system nanoACQUITY UPLC.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('nanoACQUITY UPLC System with 1D Technology', 'MS:1001767',
('Waters LC-system nanoACQUITY UPLC System with 1D Technology.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('nanoACQUITY UPLC with HDX Technology', 'MS:1001768',
('Waters LC-system nanoACQUITY UPLC with HDX Technology.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('TRIZAIC UPLC nanoTile', 'MS:1001769',
('Waters LC-system TRIZAIC UPLC nanoTile.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('GCT Premier', 'MS:1001770',
('Waters oa-ToF based GCT Premier.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('MALDI Synapt G2 HDMS', 'MS:1001771',
('Waters oa-ToF based MALDI Synapt G2 HDMS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('MALDI Synapt G2 MS', 'MS:1001772',
('Waters oa-ToF based MALDI Synapt G2 MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('MALDI Synapt G2-S HDMS', 'MS:1001773',
('Waters oa-ToF based MALDI Synapt G2 MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('MALDI Synapt G2-S MS', 'MS:1001774',
('Waters oa-ToF based MALDI Synapt G2-S MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('MALDI Synapt HDMS', 'MS:1001775',
('Waters oa-ToF based MALDI Synapt HDMS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('MALDI Synapt MS', 'MS:1001776',
('Waters oa-ToF based MALDI Synapt MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Synapt G2 HDMS', 'MS:1001777',
('Waters oa-ToF based Synapt G2 HDMS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Synapt G2 MS', 'MS:1001778',
('Waters oa-ToF based Synapt G2 MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Synapt G2-S HDMS', 'MS:1001779',
('Waters oa-ToF based Synapt G2-S HDMS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Synapt G2-S MS', 'MS:1001780',
('Waters oa-ToF based Synapt G2-S MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Synapt HDMS', 'MS:1001781',
('Waters oa-ToF based Synapt HDMS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Synapt MS', 'MS:1001782',
('Waters oa-ToF based Synapt MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo G2 Q-Tof', 'MS:1001783',
('Waters oa-ToF based Xevo G2 Q-Tof.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo G2 Tof', 'MS:1001784',
('Waters oa-ToF based Xevo G2 Tof.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo Q-Tof', 'MS:1001785',
('Waters oa-ToF based Xevo Q-Tof.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('3100', 'MS:1001786',
('Waters quadrupole based 3100.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Acquity SQD', 'MS:1001787',
('Waters quadrupole based Acquity SQD.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Acquity TQD', 'MS:1001788',
('Waters quadrupole based Acquity TQD.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Quattro micro GC', 'MS:1001789',
('Waters (triple) quadrupole based Quattro micro GC.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo TQ MS', 'MS:1001790',
('Waters quadrupole based Xevo TQ MS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo TQD', 'MS:1001791',
('Waters quadrupole based Xevo TQD.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo TQ-S', 'MS:1001792',
('Waters quadrupole based Xevo TQ-S.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('SQ Detector 2', 'MS:1002274',
('Waters quadrupole based SQ Detector 2.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo G2-S Tof', 'MS:1002275',
('Waters oa-ToF based Xevo G2-S Tof.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo G2-S QTof', 'MS:1002276',
('Waters oa-ToF based Xevo G2-S QTof.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('AutoSpec Premier', 'MS:1002277',
('Waters AutoSpec Premier magnetic sector instrument.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('SYNAPT G2-Si', 'MS:1002726',
('Waters Corporation SYNAPT G2-Si orthogonal acceleration '
'time-of-flight mass spectrometer.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('MALDI SYNAPT G2-Si', 'MS:1002727',
('Waters Corporation MALDI SYNAPT G2-Si orthogonal '
'acceleration time-of-flight mass spectrometer.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Vion IMS QTof', 'MS:1002728',
('Waters Corporation Vion IMS QTof orthogonal acceleration '
'time-of-flight mass spectrometer.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo G2-XS Tof', 'MS:1002729',
('Waters Corporation Xevo G2 XS Tof orthogonal acceleration '
'time-of-flight mass spectrometer.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo TQ-XS', 'MS:1002730',
('Waters Corporation Xevo TQ-XS triple quadrupole mass '
'spectrometer.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo TQ-S micro', 'MS:1002731',
('Waters Corporation Xevo TQ-S micro triple quadrupole mass '
'spectrometer.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Synapt XS', 'MS:1003183',
('Waters oa-ToF based Synapt XS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('SELECT SERIES Cyclic IMS', 'MS:1003184',
('Waters oa-ToF based SELECT SERIES Cyclic IMS.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('SELECT SERIES MRT', 'MS:1003185',
('Waters oa-ToF based SELECT SERIES MRT.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Xevo G2-XS QTof', 'MS:1003252',
('Waters Corporation Xevo G2-XS QTof quadrupole time-of-flight '
'mass spectrometer.'),
'instrument model',
['Waters instrument model', 'instrument model']),
InstrumentModel('Thermo Finnigan instrument model', 'MS:1000125',
('ThermoFinnigan from Thermo Electron Corporation instrument '
'model.'),
'instrument model',
['Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Thermo Electron instrument model', 'MS:1000492',
('Thermo Electron Corporation instrument model.'),
'instrument model',
['Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Finnigan MAT instrument model', 'MS:1000493',
('Finnigan MAT instrument model.'),
'instrument model',
['Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Thermo Scientific instrument model', 'MS:1000494',
('Thermo Scientific instrument model.'),
'instrument model',
['Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('IonSpec instrument model', 'MS:1000123',
('IonSpec corporation instrument model.'),
'instrument model',
['Varian instrument model', 'instrument model']),
InstrumentModel('1200 series LC/MSD SL', 'MS:1000467',
('The 1200 Series LC/MSD SL ion trap belongs to the Agilent '
'LC/MSD ion trap family. It provides fast polarity switching '
'and multisignal data acquisition capabilities in a single '
'run while also providing 5 stages of automated data '
'dependent MS2 and 11 stages of manual MS2.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6110 Quadrupole LC/MS', 'MS:1000468',
('The 6110 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with an entry level '
'single quadrupole mass spectrometer from the 6100 Series of '
'Agilent quadrupole mass spectrometers. 6110 Quadrupole mass '
'spectrometer has m/z range of 10-1500 and 2500 u/s scan '
'speed. It proves useful for wide range of SIM quantitative '
'applications.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6120A Quadrupole LC/MS', 'MS:1000469',
('The 6120A Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a single quadrupole '
'mass spectrometer from the 6100 Series of Agilent mass '
'spectrometers. 6120 quadrupole mass spectrometer has m/z '
'range of 10-1500, 2500 u/s scan speed and utilizes multiple '
'signal acquisition.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6130 Quadrupole LC/MS', 'MS:1000470',
('The 6130 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a single quadrupole '
'mass spectrometer from the 6100 series of Agilent mass '
'spectrometers. The 6130 quadrupole mass spectrometer has m/z '
'range of 2-3000, 2500 u/s scan speed in standard mode and '
'5250 u/s speed in fast-scan mode. It also uses multiple '
'signal acquisition.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6140 Quadrupole LC/MS', 'MS:1000471',
('The 6140 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a single quadrupole '
'mass spectrometer from the 6100 Series of Agilent quadrupole '
'mass spectrometers. 6140 Quadrupole mass spectrometer has '
'm/z range of 10-1350, 2500 u/s scan speed in standard mode '
'and 10000 u/s speed in fast-scan mode. It also uses multiple '
'signal acquisition.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6210 Time-of-Flight LC/MS', 'MS:1000472',
('The 6210 Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer. This time of flight mass '
'spectrometer has a m/z range of 50-12000, mass accuracy of '
'less than 2 ppm and resolution greater than 13,000 at m/z '
'2722. It has multiple ion sources and can be used with '
'multimode ion sources.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6310 Ion Trap LC/MS', 'MS:1000473',
('The 6310 Ion Trap LC/MS is a Agilent liquid chromatography '
'instrument combined with a 6300 series Agilent ion trap. It '
'has a mass range of 50-2200 between 0.6 to 0.35 resolution '
'and mass range of 200-4000 with resolution of 3-4. The scan '
'speed varies from 1650-27000 for the respective mass ranges.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6320 Ion Trap LC/MS', 'MS:1000474',
('The 6320 Ion Trap LC/MS is a Agilent liquid chromatography '
'instrument combined with a 6300 series Agilent ion trap. It '
'has a mass range of 50-2200 between 0.6 to 0.25 resolution '
'and mass range of 200-4000 with resolution of less than 3. '
'The scan speed varies from 1650-27000 for the respective '
'mass ranges.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6330 Ion Trap LC/MS', 'MS:1000475',
('The 6330 Ion Trap LC/MS is a Agilent liquid chromatography '
'instrument combined with a 6300 series Agilent ion trap. It '
'has a mass range of 50-2200 between 0.6 to 0.25 resolution '
'and mass range of 200-4000 with resolution of less than 3. '
'The scan speed varies from 1650-27000 for the respective '
'mass ranges.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6340 Ion Trap LC/MS', 'MS:1000476',
('The 6340 Ion Trap LC/MS is a Agilent liquid chromatography '
'instrument combined with a 6300 series Agilent ion trap. It '
'has a mass range of 50-2200 between 0.6 to 0.25 resolution '
'and mass range of 200-4000 with resolution of less than 3. '
'The scan speed varies from 1650-27000 for the respective '
'mass ranges.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6410 Triple Quadrupole LC/MS', 'MS:1000477',
('The 6410 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer. Mass range of the mass '
'spectrometer is 15-1650 m/z, resolution is at three settings '
'of 0.7 u (unit), 1.2 u (wide) and 2.5 u (widest). The mass '
'accuracy for 6410 mass spectrometer is 0.1 across the mass '
'range. The collision cell is a hexapole with linear '
'acceleration.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('1200 series LC/MSD VL', 'MS:1000478',
('The LC/MSD VL ion trap is part of the family of Agilent ion '
'trap mass spectrometers. It has ESI, APCI and APPI ion '
'sources and is a useful ion trap when the amount of sample '
'is not the limiting factor.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6220 Time-of-Flight LC/MS', 'MS:1000675',
('The 6220 Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer. This time of flight mass '
'spectrometer has a m/z range of 50-12000, mass accuracy of '
'less than 2 ppm and resolution greater than 13,000 at m/z '
'2722. It has multiple ion sources and can be used with '
'multimode ion sources.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6510 Quadrupole Time-of-Flight LC/MS', 'MS:1000676',
('The 6510 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer. This time of flight mass '
'spectrometer has a m/z range of 50-12000, mass accuracy of '
'less than 2 ppm and resolution greater than 13,000 at m/z '
'2722. It has multiple ion sources and can be used with '
'multimode ion sources.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6520A Quadrupole Time-of-Flight LC/MS', 'MS:1000677',
('The 6520A Quadrupole Time-of-Flight LC/MS is a Agilent '
'liquid chromatography instrument combined with a Agilent '
'time of flight mass spectrometer. This time of flight mass '
'spectrometer has a m/z range of 50-12000, mass accuracy of '
'less than 2 ppm and resolution greater than 26,000 at m/z '
'2722. It has multiple ion sources and can be used with '
'multimode ion sources.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6470A Triple Quadrupole LC/MS', 'MS:1000935',
('The 6470A Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6470B Triple Quadrupole LC/MS', 'MS:1000936',
('The 6470B Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6495C Triple Quadrupole LC/MS', 'MS:1000937',
('The 6495C Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6420 Triple Quadrupole LC/MS', 'MS:1002444',
('The 6420 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6460 Triple Quadrupole LC/MS', 'MS:1002445',
('The 6460 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer. It is similar to the 6420 but '
'adds Agilent Jet Stream (AJS) technology to increase '
'sensitivity.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6490 Triple Quadrupole LC/MS', 'MS:1002446',
('The 6490 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer. It is similar to the 6420 but '
'adds the Agilent iFunnel technology to increase sensitivity.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6550 iFunnel Q-TOF LC/MS', 'MS:1002783',
('The 6550 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6550A iFunnel Q-TOF LC/MS', 'MS:1002784',
('The 6550A Quadrupole Time-of-Flight LC/MS is a Agilent '
'liquid chromatography instrument combined with a Agilent '
'time of flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6520B Q-TOF LC/MS', 'MS:1002785',
('The 6520B Quadrupole Time-of-Flight LC/MS is a Agilent '
'liquid chromatography instrument combined with a Agilent '
'time of flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6530A Q-TOF LC/MS', 'MS:1002786',
('The 6530A Quadrupole Time-of-Flight LC/MS is a Agilent '
'liquid chromatography instrument combined with a Agilent '
'time of flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6530B Q-TOF LC/MS', 'MS:1002787',
('The 6530B Quadrupole Time-of-Flight LC/MS is a Agilent '
'liquid chromatography instrument combined with a Agilent '
'time of flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6538 Q-TOF LC/MS', 'MS:1002788',
('The 6538 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6540 Q-TOF LC/MS', 'MS:1002789',
('The 6540 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6542 Q-TOF LC/MS', 'MS:1002790',
('The 6542 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6545 Q-TOF LC/MS', 'MS:1002791',
('The 6545 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6560 Q-TOF LC/MS', 'MS:1002792',
('The 6560 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6570 Q-TOF LC/MS', 'MS:1002793',
('The 6570 Quadrupole Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6120B Quadrupole LC/MS', 'MS:1002794',
('The 6120B Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a single quadrupole '
'mass spectrometer from the 6100 Series of Agilent mass '
'spectrometers.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6150 Quadrupole LC/MS', 'MS:1002795',
('The 6150 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a single quadrupole '
'mass spectrometer from the 6100 Series of Agilent mass '
'spectrometers.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6224 Time-of-Flight LC/MS', 'MS:1002796',
('The 6224 Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6230A Time-of-Flight LC/MS', 'MS:1002797',
('The 6230A Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6230B Time-of-Flight LC/MS', 'MS:1002798',
('The 6230B Time-of-Flight LC/MS is a Agilent liquid '
'chromatography instrument combined with a Agilent time of '
'flight mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6430 Triple Quadrupole LC/MS', 'MS:1002799',
('The 6430 Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6495A Triple Quadrupole LC/MS', 'MS:1002800',
('The 6495A Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('6495B Triple Quadrupole LC/MS', 'MS:1002801',
('The 6495B Quadrupole LC/MS system is a Agilent liquid '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('7000A Triple Quadrupole GC/MS', 'MS:1002802',
('The 7000A Quadrupole GC/MS system is a Agilent gas '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('7000B Triple Quadrupole GC/MS', 'MS:1002803',
('The 7000B Quadrupole GC/MS system is a Agilent gas '
'chromatography instrument combined with a Agilent triple '
'quadrupole mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('7800 Quadrupole ICP-MS', 'MS:1002804',
('The 7800 Quadrupole ICP-MS system is a Agilent inductively '
'couple plasma instrument combined with a Agilent quadrupole '
'mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('8800 Triple Quadrupole ICP-MS', 'MS:1002805',
('The 8800 Quadrupole ICP-MS system is a Agilent inductively '
'couple plasma instrument combined with a Agilent quadrupole '
'mass spectrometer.'),
'instrument model',
['Agilent instrument model', 'instrument model']),
InstrumentModel('4700 Proteomics Analyzer', 'MS:1000140',
('Applied Biosystems/MDS SCIEX 4700 Proteomics Analyzer MS.'),
'instrument model',
['Applied Biosystems instrument model', 'instrument model']),
InstrumentModel('Voyager-DE PRO', 'MS:1000203',
('Applied Biosystems/MDS SCIEX Voyager-DE PRO MS.'),
'instrument model',
['Applied Biosystems instrument model', 'instrument model']),
InstrumentModel('Voyager-DE STR', 'MS:1000204',
('Applied Biosystems/MDS SCIEX Voyager-DE STR MS.'),
'instrument model',
['Applied Biosystems instrument model', 'instrument model']),
InstrumentModel('4800 Proteomics Analyzer', 'MS:1000658',
('Applied Biosystems|MDS SCIEX 4800 Proteomics Analyzer.'),
'instrument model',
['Applied Biosystems instrument model', 'instrument model']),
InstrumentModel('Pegasus HRT', 'MS:1001801',
('LECO high resolution time-of-flight GC mass spectrometer.'),
'instrument model',
['LECO instrument model', 'instrument model']),
InstrumentModel('Citius HRT', 'MS:1001802',
('LECO high resolution time-of-flight LC mass spectrometer.'),
'instrument model',
['LECO instrument model', 'instrument model']),
InstrumentModel('Pegasus', 'MS:1001803',
('LECO GC time-of-flight mass spectrometer.'),
'instrument model',
['LECO instrument model', 'instrument model']),
InstrumentModel('TruTOF', 'MS:1001804',
('LECO bench-top GC time-of-flight mass spectrometer.'),
'instrument model',
['LECO instrument model', 'instrument model']),
InstrumentModel('Pegasus 4D', 'MS:1001945',
('LECO nominal mass resolution time-of-flight GCxGC mass '
'spectrometer.'),
'instrument model',
['LECO instrument model', 'instrument model']),
InstrumentModel('Pegasus III', 'MS:1002278',
('LECO nominal mass resolution time-of-flight GC mass '
'spectrometer.'),
'instrument model',
['LECO instrument model', 'instrument model']),
InstrumentModel('Pegasus BT', 'MS:1002719',
('LECO bench-top GC time-of-flight mass spectrometer.'),
'instrument model',
['LECO instrument model', 'instrument model']),
InstrumentModel('HCT', 'MS:1000160',
("Bruker Daltonics' HCT: ESI Q-TOF, Nanospray, APCI, APPI."),
'instrument model',
['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('HCTplus', 'MS:1000161',
("Bruker Daltonics' HCTplus: ESI Q-TOF, Nanospray, APCI, APPI."),
'instrument model',
['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('HCTultra', 'MS:1000698',
("Bruker Daltonics' HCTultra: ESI TOF, Nanospray, APCI, APPI."),
'instrument model',
['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('HCTultra PTM', 'MS:1000699',
("Bruker Daltonics' HCTultra PTM: ESI TOF, Nanospray, APCI, "
'APPI, PTR.'),
'instrument model',
['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('HCTultra ETD II', 'MS:1000700',
("Bruker Daltonics' HCTultra ETD II: ESI Q-TOF, Nanospray, "
'APCI, APPI, ETD.'),
'instrument model',
['Bruker Daltonics HCT Series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('esquire 4000', 'MS:1000156',
("Bruker Daltonics' esquire 4000: linear ion trap, ESI, MALDI, "
'Nanospray, APCI, APPI.'),
'instrument model',
['Bruker Daltonics esquire series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('esquire 6000', 'MS:1000157',
("Bruker Daltonics' esquire 6000: linear ion trap, ESI, MALDI, "
'Nanospray, APCI, APPI.'),
'instrument model',
['Bruker Daltonics esquire series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('autoflex II', 'MS:1000148',
("Bruker Daltonics' autoflex II: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('autoflex TOF/TOF', 'MS:1000149',
("Bruker Daltonics' autoflex TOF/TOF MS: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('microflex', 'MS:1000177',
("Bruker Daltonics' microflex: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('OmniFlex', 'MS:1000183',
("Bruker Daltonics' OmniFlex: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('ultraflex', 'MS:1000201',
("Bruker Daltonics' ultraflex: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('ultraflex TOF/TOF', 'MS:1000202',
("Bruker Daltonics' ultraflex TOF/TOF: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('autoflex III smartbeam', 'MS:1000696',
("Bruker Daltonics' autoflex III smartbeam: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('microflex LT', 'MS:1000701',
("Bruker Daltonics' microflex LT: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('ultraflex III TOF/TOF', 'MS:1000705',
("Bruker Daltonics' ultraflex III TOF/TOF: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('microflex LRF', 'MS:1001543',
("Bruker Daltonics' microflex LRF: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('ultrafleXtreme', 'MS:1001544',
("Bruker Daltonics' ultrafleXtreme: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('microflex II', 'MS:1001550',
("Bruker Daltonics' microflex II: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('autoflex II TOF/TOF', 'MS:1001553',
("Bruker Daltonics' autoflex II TOF/TOF: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('autoflex III TOF/TOF smartbeam', 'MS:1001554',
("Bruker Daltonics' autoflex III TOF/TOF smartbeam: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('autoflex', 'MS:1001555',
("Bruker Daltonics' autoflex: MALDI TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('rapifleX', 'MS:1003122',
("Bruker Daltonics' rapiflex: MALDI TOF/TOF."),
'instrument model',
['Bruker Daltonics flex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('BioTOF II', 'MS:1000151',
("Bruker Daltonics' BioTOF II: ESI TOF."),
'instrument model',
['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('BioTOF-Q', 'MS:1000152',
("Bruker Daltonics' BioTOF-Q: ESI Q-TOF."),
'instrument model',
['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('BioTOF', 'MS:1001537',
("Bruker Daltonics' BioTOF: ESI TOF."),
'instrument model',
['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('BioTOF III', 'MS:1001538',
("Bruker Daltonics' BioTOF III: ESI TOF."),
'instrument model',
['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('UltroTOF-Q', 'MS:1001539',
("Bruker Daltonics' UltroTOF-Q: ESI Q-TOF (MALDI optional)."),
'instrument model',
['Bruker Daltonics BioTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('microTOF LC', 'MS:1000178',
("Bruker Daltonics' microTOF LC: ESI TOF, Nanospray, APCI, "
'APPI.'),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('micrOTOF', 'MS:1000702',
("Bruker Daltonics' micrOTOF: ESI TOF, APCI, APPI."),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('micrOTOF-Q', 'MS:1000703',
("Bruker Daltonics' micrOTOF-Q: ESI Q-TOF, Nanospray, APCI, "
'APPI.'),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('micrOTOF-Q II', 'MS:1000704',
("Bruker Daltonics' micrOTOF-Q II: ESI Q-TOF, Nanospray, APCI, "
'APPI.'),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('micrOTOF II', 'MS:1001540',
("Bruker Daltonics' micrOTOF II: ESI TOF, Nanospray, APCI, "
'APPI.'),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('impact', 'MS:1002077',
("Bruker Daltonics' impact: ESI Q-TOF, Nanospray, APCI, APPI, "
'GC-APCI, CaptiveSpray.'),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('compact', 'MS:1002280',
("Bruker Daltonics' compact: ESI Q-TOF, Nanospray, APCI, APPI, "
'GC-APCI, CaptiveSpray.'),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('micrOTOF-Q III', 'MS:1002299',
("Bruker Daltonics' micrOTOF-Q III: ESI Q-TOF, Nanospray, "
'APCI, APPI, GC-APCI, CaptiveSpray.'),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('impact II', 'MS:1002666',
("Bruker Daltonics' impact II."),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('impact HD', 'MS:1002667',
("Bruker Daltonics' impact HD."),
'instrument model',
['Bruker Daltonics micrOTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('amaZon ETD', 'MS:1001542',
("Bruker Daltonics' amaZon ETD: ESI quadrupole ion trap, "
'Nanospray, APCI, APPI, ETD, PTR.'),
'instrument model',
['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('amaZon X', 'MS:1001546',
("Bruker Daltonics' amaZon X: ESI quadrupole ion trap, APCI, "
'APPI, ETD, PTR.'),
'instrument model',
['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('amaZon Speed ETD', 'MS:1002300',
("Bruker Daltonics' amaZon Speed ETD: ESI quadrupole ion trap, "
'Nanospray, APCI, APPI, ETD, PTR, GC-APCI, CaptiveSpray.'),
'instrument model',
['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('amaZon Speed', 'MS:1002301',
("Bruker Daltonics' amaZon ETD: ESI quadrupole ion trap, "
'Nanospray, APCI, APPI, GC-APCI, CaptiveSpray.'),
'instrument model',
['Bruker Daltonics amaZon series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('maXis', 'MS:1001541',
("Bruker Daltonics' maXis: ESI Q-TOF, Nanospray, APCI, APPI."),
'instrument model',
['Bruker Daltonics maXis series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('maXis 4G', 'MS:1002279',
("Bruker Daltonics' maXis 4G: ESI Q-TOF, Nanospray, APCI, "
'APPI, GC-APCI, CaptiveSpray.'),
'instrument model',
['Bruker Daltonics maXis series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('maXis II', 'MS:1003004',
("Bruker Daltonics' maXis II."),
'instrument model',
['Bruker Daltonics maXis series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('solariX', 'MS:1001549',
("Bruker Daltonics' solariX: ESI, MALDI, Qh-FT_ICR."),
'instrument model',
['Bruker Daltonics solarix series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('apex IV', 'MS:1000141',
("Bruker Daltonics' apex IV: ESI, MALDI, Nanospray, APCI, "
'APPI, Qh-FT_ICR.'),
'instrument model',
['Bruker Daltonics apex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('apex Q', 'MS:1000142',
("Bruker Daltonics' apex Q: ESI, MALDI, Nanospray, APCI, APPI, "
'Qh-FT_ICR.'),
'instrument model',
['Bruker Daltonics apex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('apex ultra', 'MS:1000695',
("Bruker Daltonics' apex ultra: ESI, MALDI, Nanospray, APCI, "
'APPI, Qh-FT_ICR.'),
'instrument model',
['Bruker Daltonics apex series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('SCION SQ', 'MS:1002295',
("Bruker Daltonics' SCION SQ: GC-single quadrupole."),
'instrument model',
['Bruker Daltonics SCION series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('SCION TQ', 'MS:1002296',
("Bruker Daltonics' SCION TQ: GC-triple quadrupole."),
'instrument model',
['Bruker Daltonics SCION series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('EVOQ Elite', 'MS:1002297',
("Bruker Daltonics' EVOQ Elite: LC-triple quadrupole."),
'instrument model',
['Bruker Daltonics EVOQ series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('EVOQ Qube', 'MS:1002298',
("Bruker Daltonics' EVOQ Qube: LC-triple quadrupole."),
'instrument model',
['Bruker Daltonics EVOQ series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('timsTOF Pro', 'MS:1003005',
("Bruker Daltonics' timsTOF Pro."),
'instrument model',
['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('timsTOF fleX', 'MS:1003124',
("Bruker Daltonics' timsTOF fleX"),
'instrument model',
['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('timsTOF', 'MS:1003229',
("Bruker Daltonics' timsTOF."),
'instrument model',
['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('timsTOF Pro 2', 'MS:1003230',
("Bruker Daltonics' timsTOF Pro 2."),
'instrument model',
['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('timsTOF SCP', 'MS:1003231',
("Bruker Daltonics' timsTOF SCP."),
'instrument model',
['Bruker Daltonics timsTOF series', 'Bruker Daltonics instrument model', 'instrument model']),
InstrumentModel('AXIMA CFR MALDI-TOF', 'MS:1000607',
('Shimadzu Biotech AXIMA CFR MALDI-TOF MS.'),
'instrument model',
['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('AXIMA-QIT', 'MS:1000608',
('Shimadzu Biotech AXIMA-QIT MS.'),
'instrument model',
['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('AXIMA-CFR plus', 'MS:1000609',
('Shimadzu Biotech AXIMA-CFR plus MS.'),
'instrument model',
['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('AXIMA Performance MALDI-TOF/TOF', 'MS:1000610',
('Shimadzu Biotech AXIMA Performance MALDI-TOF/TOF MS.'),
'instrument model',
['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('AXIMA Confidence MALDI-TOF', 'MS:1000611',
('Shimadzu Biotech AXIMA Confidence MALDI-TOF (curved field '
'reflectron) MS.'),
'instrument model',
['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('AXIMA Assurance Linear MALDI-TOF', 'MS:1000612',
('Shimadzu Biotech AXIMA Assurance Linear MALDI-TOF MS.'),
'instrument model',
['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('Shimadzu MALDI-7090', 'MS:1002382',
('Shimadzu MALDI-7090: MALDI-TOF-TOF.'),
'instrument model',
['Shimadzu MALDI-TOF instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-IT-TOF', 'MS:1000604',
('Shimadzu Scientific Instruments LCMS-IT-TOF MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-2010EV', 'MS:1000605',
('Shimadzu Scientific Instruments LCMS-2010EV MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-2010A', 'MS:1000606',
('Shimadzu Scientific Instruments LCMS-2010A MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-9030', 'MS:1002998',
('Shimadzu Scientific Instruments LCMS-9030 Q-TOF MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-8060', 'MS:1002999',
('Shimadzu Scientific Instruments LCMS-8060 MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-8050', 'MS:1003000',
('Shimadzu Scientific Instruments LCMS-8050 MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-8045', 'MS:1003001',
('Shimadzu Scientific Instruments LCMS-8045 MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-8040', 'MS:1003002',
('Shimadzu Scientific Instruments LCMS-8040 MS.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('LCMS-2020', 'MS:1003003',
('Shimadzu Scientific Instruments LCMS-2020.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('GCMS-QP2010SE', 'MS:1003152',
('Shimadzu Scientific Instruments GCMS-QP2010SE.'),
'instrument model',
['Shimadzu Scientific Instruments instrument model', 'Shimadzu instrument model', 'instrument model']),
InstrumentModel('DELTA plusAdvantage', 'MS:1000153',
('ThermoFinnigan DELTA plusAdvantage MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('DELTAplusXP', 'MS:1000154',
('ThermoFinnigan DELTAplusXP MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LCQ Advantage', 'MS:1000167',
('ThermoFinnigan LCQ Advantage MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LCQ Classic', 'MS:1000168',
('ThermoFinnigan LCQ Classic MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LCQ Deca XP Plus', 'MS:1000169',
('ThermoFinnigan LCQ Deca XP Plus MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('neptune', 'MS:1000179',
('ThermoFinnigan NEPTUNE MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('PolarisQ', 'MS:1000185',
('ThermoFinnigan PolarisQ MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Surveyor MSQ', 'MS:1000193',
('ThermoFinnigan Surveyor MSQ MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TEMPUS TOF', 'MS:1000196',
('ThermoFinnigan TEMPUS TOF MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TRACE DSQ', 'MS:1000197',
('ThermoFinnigan TRACE DSQ MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TRITON', 'MS:1000198',
('ThermoFinnigan TRITON MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Quantum', 'MS:1000199',
('ThermoFinnigan TSQ Quantum MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LCQ Deca', 'MS:1000554',
('ThermoFinnigan LCQ Deca.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('GC Quantum', 'MS:1000558',
('GC Quantum.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LCQ Fleet', 'MS:1000578',
('LCQ Fleet.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('DSQ', 'MS:1000634',
('ThermoFinnigan DSQ GC-MS.'),
'instrument model',
['Thermo Finnigan instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('MAT253', 'MS:1000172',
('ThermoFinnigan MAT253 MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('MAT900XP', 'MS:1000173',
('ThermoFinnigan MAT900XP MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('MAT900XP Trap', 'MS:1000174',
('ThermoFinnigan MAT900XP Trap MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('MAT95XP', 'MS:1000175',
('ThermoFinnigan MAT95XP MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('MAT95XP Trap', 'MS:1000176',
('ThermoFinnigan MAT95XP Trap MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('SSQ 7000', 'MS:1000748',
('ThermoFinnigan SSQ 7000 MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ 7000', 'MS:1000749',
('ThermoFinnigan TSQ 7000 MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ', 'MS:1000750',
('ThermoFinnigan TSQ MS.'),
'instrument model',
['Finnigan MAT instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ', 'MS:1000447',
('Finnigan LTQ MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ FT', 'MS:1000448',
('Finnigan LTQ FT MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap', 'MS:1000449',
('Finnigan LTQ Orbitrap MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LXQ', 'MS:1000450',
('Finnigan LXQ MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap Discovery', 'MS:1000555',
('LTQ Orbitrap Discovery.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap XL', 'MS:1000556',
('LTQ Orbitrap XL.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ FT Ultra', 'MS:1000557',
('LTQ FT Ultra.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Surveyor PDA', 'MS:1000622',
('Surveyor PDA.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Accela PDA', 'MS:1000623',
('Accela PDA.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('ITQ 700', 'MS:1000635',
('Thermo Scientific ITQ 700 GC-MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('ITQ 900', 'MS:1000636',
('Thermo Scientific ITQ 900 GC-MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('ITQ 1100', 'MS:1000637',
('Thermo Scientific ITQ 1100 GC-MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ XL ETD', 'MS:1000638',
('Thermo Scientific LTQ XL MS with ETD.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap XL ETD', 'MS:1000639',
('Thermo Scientific LTQ Orbitrap XL MS with ETD.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('DFS', 'MS:1000640',
('Thermo Scientific DFS HR GC-MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('DSQ II', 'MS:1000641',
('Thermo Scientific DSQ II GC-MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('MALDI LTQ XL', 'MS:1000642',
('Thermo Scientific MALDI LTQ XL MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('MALDI LTQ Orbitrap', 'MS:1000643',
('Thermo Scientific MALDI LTQ Orbitrap MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Quantum Access', 'MS:1000644',
('Thermo Scientific TSQ Quantum Access MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Element XR', 'MS:1000645',
('Thermo Scientific Element XR HR-ICP-MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Element 2', 'MS:1000646',
('Thermo Scientific Element 2 HR-ICP-MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Element GD', 'MS:1000647',
('Thermo Scientific Element GD Glow Discharge MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('GC IsoLink', 'MS:1000648',
('Thermo Scientific GC IsoLink Isotope Ratio MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Exactive', 'MS:1000649',
('Thermo Scientific Exactive MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Quantum Ultra AM', 'MS:1000743',
('Thermo Scientific TSQ Quantum Ultra AM.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Quantum Ultra', 'MS:1000751',
('Thermo Scientific TSQ Quantum Ultra.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ XL', 'MS:1000854',
('Thermo Scientific LTQ XL MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Velos', 'MS:1000855',
('Thermo Scientific LTQ Velos MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Velos ETD', 'MS:1000856',
('Thermo Scientific LTQ Velos MS with ETD.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Vantage', 'MS:1001510',
('TSQ Vantage.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap Velos', 'MS:1001742',
('Finnigan LTQ Orbitrap Velos MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('ISQ', 'MS:1001908',
('Thermo Scientific ISQ single quadrupole MS with the '
'ExtractraBrite source.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Velos Plus', 'MS:1001909',
('Thermo Scientific second generation Velos.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap Elite', 'MS:1001910',
('Thermo Scientific LTQ Orbitrap Elite, often just referred to '
'as the Orbitrap Elite.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Q Exactive', 'MS:1001911',
('Thermo Scientific Q Exactive.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap Fusion', 'MS:1002416',
('Thermo Scientific Orbitrap Fusion.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap Fusion ETD', 'MS:1002417',
('Thermo Scientific Orbitrap Fusion with ETD.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Quantiva', 'MS:1002418',
('Thermo Scientific TSQ Quantiva MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Endura', 'MS:1002419',
('Thermo Scientific TSQ Endura MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Q Exactive HF', 'MS:1002523',
('Thermo Scientific Q Exactive.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ 8000 Evo', 'MS:1002525',
('Thermo Scientific TSQ 8000 Evo MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Exactive Plus', 'MS:1002526',
('Thermo Scientific Exactive Plus MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Q Exactive Plus', 'MS:1002634',
('Thermo Scientific Q Exactive Plus.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap Fusion Lumos', 'MS:1002732',
('Thermo Scientific Orbitrap Fusion Lumos mass spectrometer '
'with Tribrid architecture consisting of quadrupole mass '
'filter, linear ion trap and Orbitrap mass analyzers.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap Classic', 'MS:1002835',
('Thermo Fisher Scientific LTQ Orbitrap Classic.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Altis', 'MS:1002874',
('Thermo Scientific TSQ Altis Triple Quadrupole MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ Quantis', 'MS:1002875',
('Thermo Scientific TSQ Quantis Triple Quadrupole MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('TSQ 9000', 'MS:1002876',
('Thermo Scientific TSQ 9000 Triple Quadrupole MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Q Exactive HF-X', 'MS:1002877',
('Thermo Scientific Q Exactive HF-X Hybrid Quadrupole Orbitrap '
'MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap Exploris 480', 'MS:1003028',
('Thermo Scientific Orbitrap Exploris 480 Quadrupole Orbitrap '
'MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap Eclipse', 'MS:1003029',
('Thermo Scientific Orbitrap Eclipse mass spectrometer with '
'Tribrid architecture consisting of quadrupole mass filter, '
'linear ion trap and Orbitrap mass analyzers.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap Exploris 240', 'MS:1003094',
('Thermo Scientific Orbitrap Exploris 240 Quadrupole Orbitrap '
'MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap Exploris 120', 'MS:1003095',
('Thermo Scientific Orbitrap Exploris 120 Quadrupole Orbitrap '
'MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('LTQ Orbitrap Velos Pro', 'MS:1003096',
('Thermo Scientific LTQ Orbitrap Velos Pro, often just '
'referred to as the Orbitrap Velos Pro.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Orbitrap ID-X', 'MS:1003112',
('Thermo Scientific Orbitrap ID-X mass spectrometer with '
'Tribrid architecture consisting of quadrupole mass filter, '
'linear ion trap and Orbitrap mass analyzers.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('Q Exactive UHMR', 'MS:1003245',
('Thermo Scientific Q Exactive UHMR (Ultra High Mass Range) '
'Hybrid Quadrupole Orbitrap MS.'),
'instrument model',
['Thermo Scientific instrument model', 'Thermo Fisher Scientific instrument model', 'instrument model']),
InstrumentModel('explorer', 'MS:1000158',
('IonSpec Explorer MS.'),
'instrument model',
['IonSpec instrument model', 'Varian instrument model', 'instrument model']),
InstrumentModel('HiRes ESI', 'MS:1000162',
('IonSpec HiResESI MS.'),
'instrument model',
['IonSpec instrument model', 'Varian instrument model', 'instrument model']),
InstrumentModel('HiRes MALDI', 'MS:1000163',
('IonSpec HiResMALDI MS.'),
'instrument model',
['IonSpec instrument model', 'Varian instrument model', 'instrument model']),
InstrumentModel('OMEGA', 'MS:1000181',
('IonSpec OMEGA MS.'),
'instrument model',
['IonSpec instrument model', 'Varian instrument model', 'instrument model']),
InstrumentModel('OMEGA-2001', 'MS:1000182',
('IonSpec OMEGA-2001 MS.'),
'instrument model',
['IonSpec instrument model', 'Varian instrument model', 'instrument model']),
InstrumentModel('ultima', 'MS:1000200',
('IonSpec Ultima MS.'),
'instrument model',
['IonSpec instrument model', 'Varian instrument model', 'instrument model']),
])
# [[[end]]]
[docs]class ComponentGroup(object):
"""Represent a collection of :class:`Component` objects which are
part of a single instrument subsystem.
Attributes
----------
type: str
The name of the instrument subsystem
members: list
The components contained
order: int
The position of this group in the sequence of steps
that analytes take when passing through the instrument.
"""
def __init__(self, type, members, order):
self.type = type
self.members = list(members)
self.order = int(order)
def __repr__(self):
t = "{s.__class__.__name__}({s.type!r}, {s.members}, order={s.order})"
return t.format(s=self)
def __getitem__(self, i):
return self.members[i]
def __setitem__(self, i, v):
self.members[i] = v
def add(self, v):
self.members.append(v)
def __len__(self):
return len(self.members)
__all__ = [
"InstrumentInformation", "ComponentGroup", "Component",
"all_components_by_name", "ionization_types", "detector_types",
"analyzer_types", "inlet_types", "component"
]